APEX ENVIROTECH, INC.
<br /> STANDARD OPERATING PROCEDURES
<br /> Quarterly Monitoring Reports
<br /> SOP - 4 When practical,the groundwater sample should be collected
<br /> SAMPLE IDENTIFICATION AND CHAIN- when the water level in the well recovers to at least 80 percent
<br /> OF-CUSTODY PROCEDURES of its static level.
<br /> The sampling equipment consists of either a"Teflon"bailer,
<br /> Sample identification and chain-of�ustody procedures ensure PVC bailer,or stainless steel bladder pump with a"Teflon"
<br /> sample integrity as well as document sample possession from bladder. If the sampling system is dedicated to the well,then
<br /> the time of collection to ultimate disposal. Each sample the bailer is usually"Teflon;but the bladder pump is PVC with
<br /> container submitted for analysis is labeled to Identify the job a polypropylene bladder. In general and depending on the
<br /> number,date,time of sample collection,a sample number intended laboratory analysis,40-milliliter glass,volatile organic
<br /> unique to the sample,any in-field measurements made, analysis(VOA)vials,with"Teflon"septa,are used as sample
<br /> sampling methodology,name(s)of on-site personnel,and any
<br /> containers.
<br /> other pertinent field observations also recorded on the field
<br /> excavation or boring log. SOP - 12
<br /> MEASURING LIQUID LEVELS USING
<br /> Chain-of-custody forms are used to record possession of the WATER LEVEL METER OR INTERFACE
<br /> sample from time of collection to arrival at the laboratory. PROBE
<br /> During shipment,the person with custody of the samples will
<br /> relinquish them to the next person by signing the chain-of- Field equipment used for liquid-level gauging typically includes
<br /> custody form(s)and noting the date and time. The sample- the measuring instrument(water-level meter or interface probe)
<br /> control officer at the laboratory will verify sample Integrity, and product bailer(s). The field kit also Includes cleaning
<br /> correct preservation,confirm collection in the proper supplies(buckets,solution,spray bottles,and deion¢ed water)
<br /> container(s),and ensure adequate volume for analysis. to be used In cleaning the equipment between wells.
<br /> If these conditions are met,the samples will be assigned Prior to measurement,the instrument tip is lowered into the well
<br /> unique laboratory log numbers for identification throughout until it touches bottom. Using the previously established top-of-
<br /> analysis and reporting. The log numbers will be recorded on casing or top-of-box(.e.,wellhead vault)point,the probe cord
<br /> the chain-of-custody forms and in the legally-required log book (or halyard)is marked and a measuring tape(graduated in
<br /> maintained in the laboratory. The sample description,date hundredths of a foot)is used to determine the distance
<br /> received,client's name,and any other relevant information will between the probe end and the marking on the cord. This
<br /> also be recorded. measurement is then recorded on the liquid-level data sheet as
<br /> the"Measured Total Depth"of the well.
<br /> SOP - 5 When necessary in using the interface probe to measure liquid
<br /> LABORATORY ANALYTICAL gUALTTY levels,the probe is first electrically grounded to either the metal
<br /> ASSURANCE AND CONTROL stove pipe or another metal object nearby. When no ground Is
<br /> available,reproducible measurements can be obtained by
<br /> In addition to routine instrument calibration,replicates,spikes, clipping the ground lead to the handle of the interface probe
<br /> blanks,spiked blanks,and certified reference materials are case.
<br /> routinely analyzed at method-specific frequencies to monitor The probe tip is then lowered into the well and submerged in
<br /> precision and bias. Additional components of the laboratory
<br /> Quality Assurance/Quality Control program include: the groundwater. An oscillating(beeping)tone indicates the
<br /> robe Is in water. The robe is slowly p p raised until either the
<br /> oscillating tone ceases or becomes a steady tone. In either
<br /> 1. Participation in state and federal Laboratory case,this is the depth-to-water(DTW)indication and the DTW
<br /> accreditation/certification programs; measurement is made accordingly. The steady tone indicates
<br /> 2. Participation in both U.S.EPA Performance floating liquid hydrocarbons(FLH). In this case,the probe Is
<br /> Evaluation studies(WS and WP studies)and Inter- slowly raised until the steady tone ceases. This is the depth-to-
<br /> laboratory performance evaluation programs; product(DTP)indication and the DTP measurement Is made
<br /> accordingly.
<br /> 3. Standard operating procedures describing routine The process of lowering and raising the probe must be
<br /> and periodic instrument maintenance; repeated several times to ensure accurate measurements. The
<br /> 4. "Out-of-Control"/Corrective Action documentation DTW and DTP measurements are recorded on the Qquid-level
<br /> procedures;and, data sheet. When FLH are indicated by the probe's response,
<br /> a product baler is lowered partially through the FLH-water
<br /> 5. Mufti-level review of raw data and client reports. interface to confirm the FLH on the water surface and as.
<br /> further Indication of the FLH thickness,particularly in cases
<br /> SOP - 7 where the FLH layer Is quite thin. This measurement Is
<br /> GROUNDWATER PURGING AND recorded on the data sheet as"FLH thickness."
<br /> SAMPLING
<br /> In order to avoid crass-contamination of wells during the liquid-
<br /> Prior to water sampling,each well is purged by evacuating a level measurement process,wells are measured In the order of
<br /> minimum of three wetted well-casing volumes of groundwater. "clean"to"dirty/'(where such infcrmation_Is available). In
<br /> When required,purging will continue until either the discharge addition,all measurement equipment is cleaned with solution
<br /> water temperature,conductivity,or pH stabilize,a maximum of and thoroughly rinsed with deicnized water before use,between
<br /> ten wetted-casing volumes of groundwater have been measurements in respective wells,and at the completion of the
<br /> recovered,or the well is bailed dry. day's use.
<br />
|