I _ <br /> APEX ENVIROTECH, INC., <br /> STANDARD OPERATING PROCEDURES <br />,. Quarterly Monitoring Reports <br /> - 4 When practical,the groundwater sample should be collected <br /> SOP <br /> SAMPLE IDENTIFICATION AND CHAIN- when the water level in the well recovers to at least 80 percent <br /> OF-CUSTODY PROCEDURES of its static level. . <br /> The sampling equipment consists of either a'Tefon'bailer, <br /> Sample identification and chain�f-custody procedures ensure PVC bailer,or stainless steel bladder pump with a,'Teflon" <br /> sample integrity as well as document sample possession from bladder. If the sampling system is dedicated to the well,then <br /> the time of collection to ultimate disposal. Each sample the bailer Is usually"Teflon,"but the bladder pump is PVC with <br /> container submitted for analysis is;abeled to Identify the jab a palypropyiene bladder. In general and depending on the <br /> number,date,time of sample collection,a sample number intended laboratory analysis,40-milliliter glass,volatile organic <br /> unique to the sample,any in-field measurements made, analysis(VOA)vials,with'Teflon septa,are used as sample <br /> sampling methodology,name(s)of on-site personnel,and any containers. <br /> other pertinent field observations also recorded on the geld <br /> excavation or baring log. SOP -.12 <br /> MEASURING LIgUID LEVELS USING <br /> Chain-of-custody forms are used to record possession of the WATER LEVEL METER OR INTERFACE <br /> sample from time of collection to arrival at the laboratory. PRO13E <br /> Ouring shipment,the person with custody of the samples will <br /> relinquish them to the next person by signing the chain-cf- Field equipment used for liquid-level gauging typically includes <br /> custody form(s)and noting the date and time. The sample- the measuring instrument(water-level meter or interface probe) <br /> control officer at the laboratory wilt verify sample Integrity, and product bailer(s). The field kit also includes cleaning <br /> correct preservation,confirm collection in the proper supplies(buckets,solution,spray bottles,and deionized water) <br /> cantainer(s),and ensure adequate volume for analysis. to be used in cleaning the equipment between wells. <br /> If these conditions are met,the samples will be assigned Prior to measurement,the instrument tip is lowered into the well <br /> unique laboratory fog numbers far idenbrication throughout until it touches bottom. Using the previeusiy established top-cf- <br /> analysis and reporting.'The log numbers will be recorded on casing or top-of-box(i.e.,wellhead vault)point,the probe card <br /> the chain-af-custody forms and in the legally-required lag back (or halyard)is marked and a measuring tape(graduated in <br /> maintained in the laboratory. The sample description,date hundredths of a fact)is used to determine the distance I <br /> received,client's name,and any other relevant information wilt between the probe end and the marking on the card. This <br /> also be recorded, measurement is then recorded an the liquid-level data sheet as <br /> s <br /> the"Measured Total depth"of the well. <br /> SOP - 5 When necessary in using the interface probe to measure liquid <br /> LA13ORATORY ANALYTICAL QUALIf7Y levels,the probe is first electrically grounded to either the metal <br /> ASSURANCE AND CONTROL stave pipe or another metal object nearby. When no ground is <br /> available,reproducible measurements can be obtained by <br /> In addition to routine instrument calibration,replicates,spikes, clipping the ground lead to the handle of the interface probe <br /> blanks,spiked blanks,and certified reference materials are case. <br /> routinely analyzed at method-specific frequencies to monitor The probe tip is then lowered into the well and submerged In { <br /> precision and bias. Additional components of the laboratory the groundwater. An oscillating(beeping)tone Indicates the <br /> Quality Assurance/Quality Central program include: probe is in water. The probe is slowly raised until either the <br /> oscillating tone ceases or becomes a steady tone. In either <br /> t. Participation in state and federal laboratory case,this is the depth-to-water(DTW)indication and the DTW <br /> ' accreditatioNcertirication programs; <br /> measurement is made aceordingly. The steady tone indicates <br /> 2 Participation in both U.S.EPA Performance floating liquid hydrocarbons(FLH). In this case,the probe Is <br /> Evaluation studies(WS and WP studies)and Inter- slowly raised until the steady tone ceases. This Is the depth-tc- <br /> ', laboratory performance evaluation programs product(DTP)Indication and the DTP measurement Is made <br /> accordingly. <br /> 3. Standard operating procedures describing routine <br /> and periodic instrument maintenance; The process of lowering and raising the probe must be <br /> I. repeated several times to ensure accurate measurements. The <br /> 4. "Out-af-Control"!Corrective Action documentation DTW and DTP measurements are recorded on the riquid-level <br /> ;,,procedures;and, data sheet, When FLH are indicated by the probe's response, <br /> a product bailer Is lowered partially through the FLH-water <br /> S. Multi-level review of raw data and client reports. Interface to confirm the FLH an the water surface and as, <br /> further indication of the FLH thickness,particularly in cases <br /> Sop - where the FLH layer is quite thin. This measurement Is <br /> GROUNDWATER PURGING AND retarded on the data sheet as"FLH thickness.' <br /> SAMPLING <br /> In order to avoid cross-contamination of wells during the liquid- s <br /> Prior to water sampling,each well is purged by evacuating a <br /> level measurement process,wells are measured In the order of <br /> minimum of three wetted well-casing volumes of groundwater. "clear!to all <br /> (where such information Is e-available). In <br /> When required,purging will continue until either the discharge addition,all measurement equipment Is cleaned with solution <br /> water temperature,conductivity,or pH stabilize,a maximum of and thoroughly rinsed with deienized water before use,between <br /> measurements in respective welts,and at the completion of the <br /> ten wetted-casing volumes of groundwater have been s <br /> recovered,or the well is bailed dry. days use. <br /> iY <br />