Laserfiche WebLink
Ensoeco <br /> ISample Description <br /> Lab ID Client ID Matrix Date Sampled Containers <br /> 32165-001 MW-12 Water 04-Nov-87 2 Cntnrs <br /> -002 MW-1 Water 04-Nov-87 2 Cntnrs <br /> -003 MW-13 Water 04-Nov-87 2 Cntnrs <br /> -004 MW-3 Water 04-Nov-87 2 Cntnrs <br /> The samples were received under chain-of-custody. <br /> II Analysis Request <br /> The following analytical tests were requested. <br /> Lab ID Analysis Description <br /> 32165-1 thru 4 Total Dissolved Solids <br /> Copper and Lead <br /> III Quality Control <br /> A. Pro ect S ecific QC. No project specific QC (i .e. , spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations <br /> and procedures cause false-positive analytical results for your <br /> samples. <br /> No target parameters were detected in the method blanks associated <br /> with your samples at the reporting limit levels noted on the data <br /> sheets in the Analytical Results section. <br /> C. Laborator Control Samples. An LCS is a well-characterized matrix <br /> blank water, sand or celite) which is spiked with certain target <br /> parameters and analyzed at approximately 10% of the sample load in <br /> order to establish method-specific control limits. The LCS <br /> results associated with your samples follow: <br />