My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_3
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FILBERT
>
110
>
3500 - Local Oversight Program
>
PR0545039
>
SITE INFORMATION AND CORRESPONDENCE_3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 11:11:06 AM
Creation date
12/10/2019 10:13:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
3
RECORD_ID
PR0545039
PE
3528
FACILITY_ID
FA0010186
FACILITY_NAME
DEL MONTE FOODS PLNT #33 - DISCO WH
STREET_NUMBER
110
Direction
N
STREET_NAME
FILBERT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15702009
CURRENT_STATUS
02
SITE_LOCATION
110 N FILBERT ST
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- hn KLEINFELDER <br /> Table 1 - System Operating and Sampling Results <br /> Paialneter'Evaivated . > ux � mN' M:efYod Used-r <br /> x., <br /> Combined Vent Well Flowrate Anemometer 65 scfm <br /> Estimated Dilution Flowrate Anemometer 185 scfln <br /> Combustion Air Flowrate Blower Specifications 250 scfm <br /> Stack Flowrate at Outlet Sample Point Summation of Above 500 scfm <br /> System Vacuum Magnahelic Gauge - 40 in we <br /> Inlet Temperature Thermometer 65.7 deg F <br /> Chamber Temperature Thermal System Readout 1400 deg F <br /> Inlet Concentration(TPH) Analytical Results 1800 ppm <br /> Inlet Concentration (Benzene) Analytical Results 1.4 ppm <br /> Outlet Concentration (TPH) Analytical Results 0.13 ppin <br /> y� Outlet Concentration (Benzene) -Analytical Resttlts ND <br /> 1 In general the system operated within expected parameters, although the well flow was below <br /> anticipated levels. Concentrations of 1,2 DCA were not detected in the inlet stream to the <br /> system. It is assumed that either the 1,2 DCA has migrated off the source area, or the TPH-g <br /> concentrations altered the detection levels during analysis. It was also noted that the maximum <br /> hydrocarbon levels detected in the air stream entering the control equipment was greater (1800 <br /> ppm) than originally anticipated (500 ppm). We expect to run a flow rate of approximately 150 <br /> cfm for the duration of the remediation. <br /> The estimated extraction rate and emission rate for TPH and benzene were calculated using the <br /> analytical sample results input into the following equation: <br /> (C_)'(dugll� CF ftn ).(9E-5 miml-lb <br /> J 111 ppm/// min day•ft ug <br /> Il where: <br /> I F= System flowrate (65 scfm at the inlet, 315 scfm at the outlet) <br /> d= 4.125 for TPH, 3.25 for benzene <br /> C= Concentration of COC at the sample point <br /> Using the above equation, the emission rates and corresponding efficiencies for system were <br /> calculated and provided in Table 2: <br /> If <br /> 1 <br /> i <br /> 12280.REM2/STOC3R881 Page 2 to 4 <br /> Copyright 2003,Kleinfelder,Inc. June 20,2003 <br />
The URL can be used to link to this page
Your browser does not support the video tag.