I 1 <br /> I <br /> i <br /> �� K.LEINFEL DER <br /> 5.2. . ANALYTICAL METHODS AND REPORTED RANGES <br /> Each of.the groundwater samples collected were submitted for analysis. The following is a list of <br /> the requested analyses and the reported ranges for groundwater samples obtained from the <br /> ff monitoring wells sampled, <br /> 1 - <br /> • Total Petroleum Hydrocarbons as gasoline [non-detect to 160,000 ug/1] <br /> • Benzene [non-detect to 25,000 ug/11 <br /> • Toluene [non-detect 42,000 ug/l] <br /> • Ethylbenzene [non-detect 3,500 ug/11 <br /> • Xylene [non-detect 17,000 ug/1] <br /> 1,2 DCA [non-detect to 2,100 ug/1] <br /> • EDB [non-detect to 1,100 ug/1] <br /> TBA [all non-detect <0.50 ug/l] <br /> • MTBE [non-detect to 1.449/11 <br /> • DIPE [all non-detect<0.50 ug/1] <br /> •. ETBE [all non-detect<0.50 ug/1] <br /> • TAME [all non-detect<0.50 ug/1] <br /> For a summa of analytical data for the analytes listed above, <br /> ry yt ytplease see Table 2 behind the <br /> "Tables"tab of this report. . <br /> 1,2-DCA was detected in six of the eight groundwater samples analyzed with concentrations <br /> i ranging from 0,57 ug/l (MW-DIS-2) to 2,100 ug/l (NPI-80'). This sampling event marks the <br /> first time a groundwater sample was collected for analysis from MW-DIS-15 since.it was <br /> installed in February 2003. 1,2-DCA was detected in MW-DIS-15 with a concentration of 10 <br /> ug/1. The remaining four groundwater samples showed non-detect concentrations of 1,2-DCA at <br /> or above the laboratory reporting limit(ND <0.5 ug/1). The PMCL for 1,2-DCA is 5 ug/l. <br /> TPH-g and BTEX compounds were also detected in five of the twelve groundwater samples. <br /> The highest noted concentrations. were seen in the samples collected from within the former <br /> service station footprint (MW-DIS-1,. NPI-70', NP1-80% and NP1-90'), whereas the lowest . <br /> concentrations detected were seen in MW-DIS-2 located northwest of the former service station <br /> tank area. <br /> The groundwater sample collected from MW-DIS-15 was also analyzed for the four oxygenates <br /> MTBE, DIPE, ETBE, and TAME. None of the oxygenates were detected in the sample. MTBE <br /> was detected in the groundwater sample collected from MW-DIS-14s with a concentration of 1.4 <br /> ug/l. MTBE was not detected in the remaining samples and no other oxygenates were detected at <br /> or above the laboratory reporting limits. <br /> { <br /> 12280.MON/ST03R524 Page 9 of 12 <br /> 0 2003,Kleinfelder,Inc May 6,2003 <br />