i <br /> l pack is seated with 2 feet of bentonite. Overlying the bentonite seal is a neat-cement grout <br /> that extends to the surface. <br /> Groundwater sampled from SB-2, SB-3, and SB-7 contained high concentrations of TPH(g) <br /> and BTEX. To establish a plume boundary -in the westerly direction, SB-6 was drilled <br /> 120 feet west of SB-2. To establish an easterly plume boundary, SB-8 was drilled 100 feet <br /> east of SB-7. Analytical results revealed that SB-6 and SB4 groundwater did not contain <br /> 1 detectable gasoline constituents. SB-6 and SB-8 were converted to 2-inch-diameter shallow <br /> monitoring wells MW-DIS-10 'and MW-DIS-9, respectively. The monitoring well <br /> construction details are presented in Appendix B. <br /> } Aquifer Pump Testing <br /> CH2M HILL performed pumping tests on monitoring wells MW-DIS-8S and MW-DIS-8D <br /> on February 16 and 17, 1995. The tests were performed to determine the hydraulic properties <br /> of the aquifer underlying the affected portion of the Disco site. The pumping tests were <br /> designed to calculate the hydraulic conductivity, transmissivity, and storativity of the <br /> uppermost and the second water-bearing zones, referred to as the A and B Zones. <br /> Pump Testing Procedures and Results <br /> Pump tests were performed with a variable-speed submersible well pump, and drawdown in <br /> ( each well was recorded with Hermit 1000 data loggers. <br /> MW-DIS-8D Pump Test <br /> The first pump test was conducted using MW-DIS-8D as the pumping well. Drawdown was <br /> logged in adjacent wells MW-DIS-2,_MW. SCIS, MW-DIS-8S, and MW-DIS-10, each <br /> � <br /> screened between 65 feet and 85 feet bgs (A Zone), and in MW-DIS-7D, which is screened( ; <br /> between125feet and 145 feet bgs (B Zone). Figure 3-1 shows the relationship of the <br /> observation wells in plan view relative to the pumping well. <br /> MW-DIS-8D was pumped for 100 minutes ata constant discharge pumping rate of 1.2 gpm. <br /> After the first 100 minutes, the pumping rate was increased to 2.1 gpm to increase the stress <br /> on the aquifer. At this higher pumping rate, the test ran 73 minutes before the pump turned <br /> off due to overheating. Time drawdown data for all observation wells are presented in <br /> Appendix C. Figure 3-2 is a hydrograph showing the water level response in the observation <br /> wells during this pump test. The hydrographs reveal that the observation well MW-DIS-7D <br /> exhibited approximately 0.5 feet 'of drawdown during this test. The drawdown was <br /> insignificant in the other observation wells. <br /> MW-DIS-8S Pump Test <br /> MW-DIS-8S was pumped on February 17, 1995, using three separate pumping rates. The <br /> first of these three tests was performed at a pumping rate of 5 gpm. After 14 minutes, water <br /> levels in the pumping well dropped below the pressure transducer and the test was halted. <br /> SF010030982.DOC 3-4 <br />