j SEQUOIA ANALYTICAL
<br /> 680 Chesapeake Drive • Redwood City, CA 94063
<br /> �, ;. (415) 364-9600 FAX (415) 364-9233
<br /> i'o
<br /> -; ,..w-::x:.v-..-::::::�-::::�-::r::._:__..:.uuw..,: -. .x.,,:,,.u,,..•._., ::.:s::rr�,,.,v-:xv:.,..?.L.,,,::..v~..{:.:.r,..,. r .,,.
<br /> ....:.:........
<br /> Wo
<br /> F" i:..::.si, :ish+,v.r+:ry.:}i.S..:2�:vvvk'^:C_r�;r•%m�:=:'a;7:.,�?'wrfr-.'fwa.-'ay.,�,�,;:.;Rw;;»:Yr;ri{ ..,ca�,�,..x:::.RESNFi Client{Project I'D: r W0365.02, Stock.v:.vton Smith Canal
<br /> 1710 Main Street Matrbc: Soil =u
<br /> Escalon, CA r2OAention: JoLane OC Sample Group: 3H23301-2,4-5,7-12 Reported: Aub 18, 1993 in
<br /> '-:,c'4"• ..1.^.'v..\:!".'r ..'ori{.:{:'i.r?::-' 9x{fiVxyvi:-:-::--ry':is{U
<br /> :_ r.. �':'�;trn ysfi'.__ •rxauu:u,ru•
<br /> •{ ,i.
<br /> : w.
<br /> i '. . .v.x..:`� r�:[�00.-0.'3}:-04vr.v,v.$i'L:�.'•.•vF�.t4+' !f .- .r-.i.M. �iC4.i' rvAm+n.,.n.r..r.....tr.....v_..Y.k..0....:r.vC.+6+�vnvr+.+ii4.-,.v.+nvvmwxvr:'.r=?44+'Y^+- IFS:-^'�c. *}. r'�pppyibOWC�+.wxr.
<br /> QUALITY CONTROL DATA REPORT
<br /> ANALYTE Ethyl-
<br /> Benzene Toluene Benzene Xylenes Diesel
<br /> i Method: EPA 8020 EPA 8020 EPA 8020 EPA 8020 EPA 8015
<br /> l Analyst: E.Cunanan E Cunanan E.Cunanan E.Cunanan C.Lee
<br /> Conc. Spiked: 0.20 0.20 0.20 0.60 15
<br /> Units: mg/Kg mg/Kg mg/Kg mg/Kg mg/Kg
<br /> LCS Batch#: BLKo81193 BI-KO81193 BLKD81193 BLK081193 BLK081293
<br /> Date Prepared: 8/11/93 8/11/93 8/11/93 8/11/93 8/12/93
<br /> Date Analyzed: 8/11/93 8/11/93 8/11/93 8/11/93 8/12/93
<br /> instrument i.D.#: GCHP-18 GCHP-18 GCHP-18 GCHP-18 GCHP-58
<br /> LCS%
<br /> Recovery: 95 100 100 98 67
<br /> Control Limits: 60-140 60-140 60.140 60-140 50.150
<br /> irJ
<br /> ...,,.-.:?-'+.=-'.;....c.io.:{: ..h -t {-,...:--:-:-::^%rtiv.;F°r+;„Yo:'�:v`�::;�:::c-:c;;{ai;;ic;iv.v{n:tr�:.o4'r.t-:v.:. "^,.^}v:?;.:x?:cc:T._::i9 -•r.{:£v-h:.,,?'nv'-.'x;r.:_..:vv_=[::Y2i=;
<br /> ._4... ....}..... r.w::.:..................... 1. a.. .: ry r-:..........:...v u.{'S.. .:} ..�.1:. .A.:::k�'. syr
<br /> v::---., +�..}v O[:i:i::i...� ....]?:S V:.9;+hiY• ....................... .......i:4.:Lk.4\ +. ... ..c-ir-v-+- r_[v
<br /> MS/MSD
<br /> Batch#: 3H26502 3H26502 3H26= 3H28502 3H44003
<br /> Date Prepared: 8/11/93 8/11/93 9/11/93 8/11/93 8/12/93
<br /> J Date Analyzed: 8/11/93 8/11/93 8/11/93 8/11/93 8/12/93
<br /> Instrument I.D.#: GCHP-18 GCHP-18 GCHP-18 GCHP-18 GCHP-513
<br /> Matrix Spike
<br /> % Recovery: 95 95 95 97 73
<br /> F< Matrix Spike
<br /> Duplicate%
<br /> Recovery: 100 105 105 103 80
<br /> Relative%
<br /> Difference: 5.1 10 10 6.0 9.2
<br /> I
<br /> SEQUOIA ANALYTICAL Please Note:
<br /> :.'.:j
<br /> The LCS is a control sample of known,interferent free matrix that is analyzed using the same reagents,
<br /> s ti r preparation and analytical methods employed for the samples. The LCS%recovery data is used for I
<br /> validation of sample batch results. Due to matrix effects,the OC limits for MS/MSD's are advisory only
<br /> U and are not used to accept or reject batch results.
<br /> Vickie Tague
<br /> Project Manager 3H23301.WAT a7>
<br />
|