My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
COMPLIANCE INFO_2002 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2019 3:26:44 PM
Creation date
12/16/2019 1:48:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2010
RECORD_ID
PR0231223
PE
2361
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
01
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
473
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ti SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton,California 95202-3029 <br /> ' Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sit?ov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> ri 4 <br /> Facility addr UST# <br /> Product <br /> Facilit Contact: Ti e: Phone: <br /> nitori anel: Piping system: Overfill prevention: <br /> R. L Sp ressurized El Suction El Gravity :wechanical ❑Audible/visual <br /> Inspection type: Violations: <br /> outine )(Monitoring Certification ❑Installation ❑Other: ❑MI-RDetect ❑M2-RPrev ❑M-3 Both <br /> # Code Section <br /> VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R V=Violation; RV=Re eat Violation V <br /> I HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b)& c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form) <br /> 4 1 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 b Monitoring Program(Monitoring&Response Plan)is current and approved by the local agency. <br /> 6 CCR 2712 i) Monitoring Ian is onsite. <br /> 7 CCR 2712 b Maintenance&monitoring records M 1 <br /> 8 CCR 2643 d Daily monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 1 CCR 2632(c)(2) UST monitoring system is present (M1) <br /> I I CCR 2630 d) UST system monitoring equipment is properly located to detect a leak (M 1) <br /> 12 HSC 25291 b) UST system monitoring equipment isoperational (M2) <br /> 13 CCR 2636(t)(1) Continuous monitoring system for underground piping&UDC is present (M 1) <br /> 14 CCR 2631 a) Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping flow to a collection sum <br /> 17 HSC 25291 t Line leak detector(s)are installed (M 1) <br /> 18 CCR 2635(b)(1) Spill container ('VI 2) <br /> 19 CCR 2635(b)(2) Overfill prevention system (M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases (M1) <br /> 23 CCR 2715 Designated Operator:(a)Statement from UST owner; (c-e)Monthly inspection;(f)Employee training <br /> 24 CCR 2638 a) Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (M 1) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636(t)(4) Annual line tightness test (M1) <br /> 28 CCR 2661 t) Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 e) Biennial tightness test of gravity piping(pre-January 1, 1984) <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping(pre-January I, 1984) (M 1) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 b) Permit to temporarily close UST system <br /> 35 HSC 25298 c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices 1 _ <br /> 37 HSC 25298 a) Illegal abandonment of UST s stem _ <br /> 38 Other: <br /> EHD INSPECTO PHONE: Ulr <br /> zzz _� Sentic system: <br /> Serves>_20 peoplo'day <br /> RECE VED TITLE: - Receives other than sanitary waste <br /> ,/ Other disnosal methods: <br /> (/�/�� - Dry wells/French mains <br /> EHD 23-02-002 REV 05/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.