SS200 Series Properties @ 75°F (24°C) <br /> Product Working Time Minutes Fixture Time Minutes <br /> SS208/SS214B 8-12 >25 <br /> SS214/SS214B 17-22 >35 <br /> SS218/SS218B 30-45 >80 <br /> SAFETY AND HANDLING <br /> Read Material Safety Data Sheet before handling or using this product The A component adhesive contains methyl methacrylate monomer and is <br /> flammable. Always use in a well-ventilated area. Floor-level extraction and large quantities of moving air greatly facilitate ventilation. Activator <br /> (Component B)contains peroxide. Both materials must be stored in a cool place away from sources of heat and open flames or sparks. Keep <br /> containers closed when not in use. Prevent contact with skin and eyes. In case of skin contact,wash with soap and water. In case of eye contact,flush <br /> with water for 15 minutes and seek immediate medical attention. Harmful if swallowed. Keep out of reach of children. <br /> MIXING AND APPLICATION <br /> EXOTHERM: The chemical curing reaction that occurs when components A and B are mixed generates heat. The amount of heat generated is <br /> controlled by the mass and thickness of the mixed product. Large masses over 1/2 inch thick can develop heat in excess of 250°F/121`C and can <br /> generate harmful,flammable vapors. Large curing masses should be carefully moved to a well-ventilated area where the chance of personal contact is <br /> minimized. <br /> CURING:The term Open working time is the approximate time after mixing components A and B,depending on the bonding conditions that the <br /> adhesive remains fluid and bondable. Fixture time is the approximate time after mixing components A and B required for the adhesive to develop <br /> sufficient strength to allow careful movement,unclamping or de-molding of assembled parts. Parts can generally be put in service when 80 percent of <br /> full strength is developed. The time to achieve 80%cure is approximately 2-3 times that required for fixturing.The working and fixture times presented <br /> in this bulletin are based on laboratory tests performed at 75°F/24°C. Higher temperatures speed the curing reaction,which reduces open working time <br /> and speeds the development of strength. The reverse is true for lower temperatures. If significant variation in temperatures or application at very high <br /> or low temperatures is anticipated,contact your IPS representative for technical assistance. <br /> DISPENSING EQUIPMENT: Dispensing directly from disposable cartridges or meter-mix-dispensing equipment is strongly recommended. Both <br /> methods employ convenient static motionless mixer technology. Product supplied in pre-measured cartridges is dispensed from approved manual or <br /> pneumatic powered guns. Contact your IPS representative for information and availability. <br /> When meter-mix dispense systems are used,care must be taken to assure compatibility between the adhesive components and the materials in the <br /> equipment that they contact. All wetted metal components should be constructed of stainless steel or aluminum or have a sufficient thickness of <br /> chemically resistant material that prevents contact between the adhesive components and the base metal. Contact with copper,zinc,brass or other <br /> alloys containing these matehals must be strictly prevented. All non-metallic seals and gaskets should be fabricated from Teflon®or UHMW <br /> polyethylene based materials. Natural rubber,nitrile rubber(BONA),neoprene and Vfton®are not acceptable.Ethylene-propylene rubbers,such as <br /> Nordel®may be used for ram follower plate o-rings,but a polyethylene sheet most be used to prevent direct contact with the adhesive. <br /> APPLICATION: Follow instructions provided or contact your IPS representative for proper preparation of dispensing equipment and substrates prior to <br /> starting the bonding process. Always dispense a quantity of adhesive at start-up to assure that the adhesive exiting the tip of the mixer is the proper <br /> color and is uniform,without streaks. If previously opened or aged material is being used,allow the purged material to cure to assure quality before <br /> proceeding. Carefully dispense a sufficient quantity of adhesive on the substrate to assure that the bond gap will be completely filled when the parts are <br /> mated. Allow for squeeze-out at the edges of the bond to assure filling. Carefully secure or clamp parts to prevent joint movement while the adhesive <br /> sets. Do not apply excessive pressure that can cause excessively thin gaps and starve the bond line. If in doubt,use shims or spacers to set the gap. <br /> A minimum gap of 20 mils(0.020 inch)is recommended for the SS200 series products. Test the curing adhesive at the edges for fingernail hardness <br /> before removing clamps or fixtures. Use a soft faring tool to remove excess adhesive from the bonded assembly.Masking tapes or other protective <br /> barriers should be used to prevent contamination on any cosmetically sensitive areas. Partially cured adhesive can be removed with a sharp knife and <br /> any cured adhesive may be removed by sanding or scraping. <br /> CLEAN UP: Adhesive components and mixed adhesive should be removed from mixing and application equipment with a suitable industrial solvent or <br /> cleaner before the mixed adhesive cures. Once the adhesive cures,soaking in a strong solvent or paint remover will be required to soften the adhesive <br /> for removal.If the bonds are exposed to UV rays then use of plasticizers such as Dibutyl-Phalate(DBP)is recommended,or contact your IPS <br /> representative for additional information.Any clean-up of the bonded assembly using industrial solvents is not recommended as it could affect the cure. <br /> STORAGE AND SHELF LIFE <br /> The shelf life of Components A and B in unopened containers is approximately six months from the date the product is shipped from IPS facilities. Shelf <br /> life is based on steady state storage between 50`F and 80°F(100C and 27°C). Exposure,intermittent or prolonged,above 80°F/27°C will result in a <br /> reduction of the stated shelf life.Exposures above 100°F(38°C)during shipping or storage can quickly degrade Component B in cartridges or bulk <br /> containers,and must be strictly prevented. Shelf life of both components can be extended by air-conditioned or refrigerated storage between 50°F and <br /> 65°F(10°C and 18°C).KEEP FROM FREEZING. <br /> IMPORTANT NOTES <br /> a. SUBSTRATE AND APPLICATION COMPATIBILITY. The user must determine the suitability of a selected adhesive for a given substrate and <br /> application. IPS strongly recommends laboratory,shop and end-use testing that simulates the actual manufacturing and end-use environment. <br /> b. SURFACE PREPARATION: The need for surface preparation must be determined by comparative testing of prepared and unprepared substrates <br /> to assure that unprepared bonding is equivalent to or acceptable for the application relative to prepared bonding. Initial bonding tests must be <br /> followed up with simulated or actual durability tests to assure that surface conditions do not lead to degradation of the bond over time under service <br /> conditions. Subsequent changes in substrates or bonding conditions will require re-testing. <br /> c. TECHNICAL ASSISTANCE: Contact your IPS representative for questions or assistance with the selection of adhesives and methods for <br /> evaluating adhesives for your intended application. <br /> This product is intended for use by skilled individuals at their own risk. Recommendations contained herein are based on information we believe to be <br /> reliable. The properties and strength values presented above are typical properties obtained under controlled conditions at the IPS laboratory. They are <br /> intended to be used only as a guide for selection for end-use evaluation. The ultimate suitability for any intended application must be verified by the end <br /> user under anticipated test conditions. Since specific use,materials and product handling are not controlled by IPS,our warranty is limited to the <br /> replacement of defective IPS products. <br /> IPS Corp.PO Box 12729,Research Triangle Park,NC 27709• www.il)scorl).com•Toll Free:1-877-IPS GLUE•FAX(919)598-2439 SS200 9/05 <br />