My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
COMPLIANCE INFO_2002 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2019 3:26:44 PM
Creation date
12/16/2019 1:48:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2010
RECORD_ID
PR0231223
PE
2361
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
01
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
473
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIARING SYSTEM CERTIF&TION �L�F <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the lowagency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: I'o'wa poId ��� Bldg.No.: <br /> Site Address: b 12.,1 � �� i kre.• City: 5+oeKi l G Zip: 5.�O 7 <br /> Facility Contact Person: Tr mn Contact Phone No.: LL0� �3i�-P- <br /> Make/Model of Monitoring System: CeAer V T-S 3 SD Date of Testing/Servicing: 1 C_>/ 07 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the agprogriate boxes to indicatespecific equipment inspected/serviced. <br /> Tank ID: Tam 1 G Ll ar Tank ID: Q <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ular Space or Vault Sensor. Model:dun I-JA cr rf- yd�sk•l Annular Space or Vault Sensor. Model: al +1 dro 1 i <br /> Piping Sump/Trench Sensor(s). Model:-41R ►MT 09 gc� Piping Sump/Trench Sensor(s). Model:\(/K t-A-FO9509 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: T LLD Electronic Line Leak Detector. Model: 1P LLD <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(s2ecify aqui ment Ine and model in Section E on Page 2). ❑ Other(speciL equipment a and model in Section E on Pae 2), <br /> Tank ID:-OIV� 3 \G-S� Tan <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank a Probe. Model: <br /> Annular Space or Vault Sensor. Model: dro_-,4,,� ❑ Annular Space or Vau r. Model: <br /> Piping Sump/Trench Sensor(s). Model:Y 2 t7 ❑ Piping Sump/Trench Sensor(s). odel: <br /> ❑ Fill Sump Sensor(s). Model: 13Fill Sump Sensor(s). <br /> El Mechanical Line Leak Detector. Model: El Mechanical Line Leak Det Model: <br /> Electronic Line Leak Detector. Model: ❑ Electronic Lin �Laaklletector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑.T,hnIF 016rr(ill/High-Level Sensor. Model: <br /> El Other s eci a ui ment a and model in Section E on Pa e 2). ea Other(sgecify equipment a and model in Section E on Pae 2 . <br /> Dispenser ID: I+ �_ Dispenser ID: 3 + <br /> ❑ Dispenser Containment Sensor(s), Model: FrA\f 0 ❑ D' penser Containment Sensor(s). Model: 1b r 1r0 <br /> ear Valve(s). ear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). is enser Containment Floats and Chain(s). <br /> Dispenser ID: !—L t"(o Dispenser ID: '7 -f"F <br /> ❑ Dispenser Containment Sensor(s). Model: R(Z1y'D ❑ Dispenser Containment Sensor(s). Model: V <br /> ear Valve(s). hear Valve(s). <br /> Dis enser Containment Floats and Chain(s). is enser Containment Float(s)and Chain(s). <br /> _Mpenser : s <br /> _�--,__. <br /> ❑ Dispenser Con`tainmen4Sensor `_.Model. ❑ Dispenser Con o odel: <br /> -.� <br /> ❑ Shea�r.V..alve(s):'--•-- ._.._.. ....._.__�.- ._. _ ❑ ShNAt ValVe s . <br /> Obis enser Containment Floats and Chain (s). ❑-'ifs enser Containment Floats and Chains . -----------^-- <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such r ports,I have also <br /> attached a copy of the re ort; (check all that apply): ❑ System set-up farm histo re <br /> Technician Name(print): ]e a w";N • !J f t v� C ec o.� Signature: <br /> Certification No.: 4 2-3 L 5 �1- License.No.: 17 D`1 )2-0 <br /> Testing Company Name: £b Co,,,,, ''a-r�c 0- --s jk-,- Phone No.:(-70-7 <br /> Site Address: �,121 1 5-1oCy 0,.,F E-A' q 5,�0`1 Date of Testing/Servicing: /d/ C-)7 <br /> Page 1 of 3 03/01 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.