Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> a ENVIRONMENTAL.HEALTH DEPARTMEN <br /> 304 East Weber Avenue, 3`d Floor, Stockton,CA 95202-2708 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sj jov.or&hd <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date; <br /> Faci i;ty add ess: UST#" L <br /> 'x ? t f. ! 'y Product �1 r <br /> Facility Contact: Title: Phone: <br /> MPrtitor ng Panel. P'sping system: Overfill prevention: <br /> 7 t. t <br /> L � ��}0 �', ressunzed U Suction -D Gravity k Mechanical Audible/visual <br /> Inspection type: Violations: <br /> 0 Routine Monitoring Certification D Installation Other: MI-RDetect ❑M2-RPrev ❑11-3 Both <br /> # Code Sectiony <br /> VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation;RV=Re eat Violation _ <br /> 1 HSC 25284 Per nit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 (b)& c) Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c' 2) D Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712 i Monitoring&response plan is onsite <br /> 7 CCR 2712 b) Maintenance&monitoring records M1 <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pTe-January, 1, 1984 <br /> 9 HSC 25292.1 UST system is operated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present (MI) <br /> 11 CCR 2630 d UST system monitoring a ui ment is properly located to detect a leak MI <br /> 12 HSC 25291 b UST system monitorinE a ui o merit isoperational M2 <br /> 13 CCR 2630 1) Continuous monitoring system for under round piping&UDC is present Ml <br /> 14 CCR 263.1 (a) Primary containment is` rod'uct tight <br /> i 5 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636 c 1 1 All releases in secondary tin flow to a collection sum <br /> 17 t HSC 25291 (0 Line leak detector(s)are installed M1 <br /> £8 CCR 2635 (b)(1) Spill container M2 <br /> 19 CCR 2635(b)(2) Overfill prevention system- M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitorin &2'containment <br /> 21 HSC 25291 (e) Water in 2'containment analyzed&properly disposed of <br /> 22 CCR 2650 " Recording/rcoorriing of unauthorized releases Ml <br /> 23 CCR 2715 Designated O erator: a)Statement from UST owner; (c-e)Monthly inspection, Em to ce training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638 a) Annual line leak detector test M111 <br /> 26 HSC 25284.2 Annual spill containment testing <br /> 27 CCR 2636 4) .Annual line tightness test (411 <br /> 28 CCR 2661 Re air for tank/piping has had tightness test (M2 <br /> 29 CCR 2643 e) Biennial tightness test of gravity piping(pre-January 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping pre-January 1 1984) (M] <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2663 Permit to repair UST system " <br /> 33 HSC 25286 ra Permit to alter monitoring system <br /> 34 HSC 25298 Permit to tem oraril 'close UST system <br /> 35 HSC 2529$ c Permit to close UST system <br /> 36 HSC 25299(a)(9)_ Disabling leak detection devices <br /> 37 HSC 25298(a) Illegal abandonment of UST system <br /> 38 Other: <br /> EHD,INSPE 'fOR: ,. PHONE. 111C <br /> �/ G ! Lmic system: <br /> 1� �> _Serves zlU peopleiday <br /> RECEIVED By: `� l TITLE: Receives other than sanitary waste <br /> �J I Other disposal meth " <br /> Dry wells/FrenchDrains <br /> �I <br /> I <br /> FHi)23-02-002 <br />