Laserfiche WebLink
n <br /> . LEL-TECH Geotechnical Support Services <br /> MONITORING WELL FIELD LOG <br /> RC>4JEC 1�NAIfNIE~, VI 5 <br /> SAMPtwE ANA>L.YSIS PE>RFC?RMir© . Ti�H <br /> Stc�ckt�rt A ' AMP��TFNII» 14 42 <br /> SAI�flPl�fw OE?I�l7AINR(S}' 3 1f C3 A'S <br /> PJA , S15 P ROORM D 6Y SHi=R VQt�D !_q`BS ;i> <br /> CLIENT: HUNTER & ASSOCIATES DATE: 12/07/95 <br /> PROJECT MANAGER: BILL HUNTER SAMPLE LOCATION: MW-2 <br /> AMPLER: DON LIGHT START TIME: <br /> GROUNDWATER: XXX11ADOSE: OTHER: <br /> CASING ELEVATION: (FEET MSL) CASING DIAMETER: 4 INCH <br /> DEPTH TO WATER: 12.38 FEET CALCULATED CASING VOLUME: 10.84 GAL. <br /> DEPTH OF WELL: 29.00 FEET [TOTAL VOLUME PURGED: 44.0 GAL. <br /> • <br /> I"tM� L } ObL# I O IE#3: <br /> galEans : ln�t .UrrmFnrt tegraes C <br /> 0 7.4 937 20.6 CLEAR GAS ODOR <br /> 11.0 7.4 937 21.7 " <br /> 22.0 7.4 937 21.5 " <br /> 33.0 7.5 931 21.5 <br /> 44.0 7.5 937 21.3 " <br /> PURGE METHOD : CENTRIFUGAL PUMP. <br /> SAMPLE METHOD: 1 FOOT STAINLESS STEEL BAILER. <br /> DEPTH TO WATER AFTER PURGE: 12.40' DEPTH TO WATER AT SAMPLE TIME: <br /> WELL INTEGRITY: CAP AND SEAL ARE SECURE, NO LOCK IS INSTALLED. <br /> REMARKS: GOOD RECHARGE. <br /> WEATHER: OVERCAST SKIES. <br /> QUALITY CONTROL: ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH ALCONOX. <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES. <br /> WELL LOCATION: WELL IS LOCATED NORTH / NEXT TO FENCE. <br /> CONTAINMENT: D.O.T. 17 STEEL DRUM. <br /> INSTRUMENTATION: ORION pH/TEMPERATURE METER 2 POINT pH CALIBRATION (4.0 & 7.0) <br /> . ORION CONDUCTIVITY METER <br /> ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 580B PHOTO IONIZATION DETECTOR <br />