Laserfiche WebLink
SEQUOIA ANALYTICAL <br /> 680 Chesapeake Drive • Redwood City, CA 94063 <br /> (415) 364-9600 FAX (415) 364-9233 <br /> .:.RESNA- Escalon Client Project ID: w04801, PG&E Stockton Service Gtr. Sampled. Jan 12, 1993 <br /> >1710 Main Street Sample Matra: Soil Received: Jan 15, 1993 <br /> Escalon, CA 95320 Analysis Method: EPA 3550/8015 Reported: Jan 24, 1993;;: <br /> ::::Attention: Lois Frantz First Sample#: 301-2035 <br /> TOTAL EXTRACTABLE PETROLEUM HYDROCARBONS <br /> Reporting Sample Sample Sample Sample Sample Sample <br /> Analyte Limit I.D. I.D. I.D. I.D. I.D. E.D. <br /> mg/kg 301-2035 301-2036 301-2037 301-2038 301-2039 301-2040 <br /> TP-B-12' TP-EW-9 TP-13112.5' WW-7 PL-SS14 PL-SS2-5' <br /> Extractable <br /> Hydrocarbons 1.0 N.D. N.D. 550 22 27 170 <br /> Chromatogram Pattem: -- -- Non-Diesel Non-Diesel Non-Diesel Non-Diesel <br /> Mix >�C14 Mix > C14 Mix > C14 Mix C13 <br /> I <br /> fI � <br /> I <br /> . � f <br /> Quality Control Data <br /> Report Limit Multiplication Factor: 1.0 1.0 20 2.0 2.0 10 <br /> Date Extracted: 1/19/93 1/19/93 1/191/93 1/19/93 1/19/93 1/19/93 <br /> Date Analyzed: 1/19/93 1/19/93 1/20%93 1/20/93 1/20/93 1/20/93 <br /> Instrument Identification: GCHP-4 GCHP-4 GCHP-4 GCHP-4 GCHP-4 GCHP-4 <br /> 1 <br /> Extractable Hydrocarbons are quantitated against a fresh diesel standard. <br /> Analytes reported as N.D.were not detected above the stated reporting limit. i <br /> SEQUOIA ANALYTICAL i <br /> ri L� a <br /> roject Manager 301-2035.wAT <3> <br /> 1 <br />