Laserfiche WebLink
Appendix A - Historical Background <br /> River City Petroleum and Connell Motor Lift Truck <br /> Page 14 of 14 <br /> SOIL-VAPOR EXTRACTION RESULTS <br /> The catalytic oxidizer soil-vapor extraction(SVE) system began operation at the site m November <br /> 2004, and operated until late 2005 The SVE unit operated as an interum soil remediation and is <br /> connected to a total of twenty-six extractions wells on the eastern and western portions of the site <br /> The mass of hydrocarbons removed was based on analysis of soil-vapor samples The mass of <br /> extracted hydrocarbons was calculated using average hydrocarbon concentrations of influent soil- <br /> vapor sample data and average air flow rates <br /> i <br /> Advanced GeoEnvironmental,Inc <br />