My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1932
>
2300 - Underground Storage Tank Program
>
PR0231097
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2023 5:01:15 PM
Creation date
12/26/2019 1:25:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231097
PE
2361
FACILITY_ID
FA0004016
FACILITY_NAME
SUSD-CORPORATE YARD
STREET_NUMBER
1932
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
APN
11708027
CURRENT_STATUS
01
SITE_LOCATION
1932 EL PINAL DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JNIFIED PROGRAM CONSOLIDATED FORW <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 (two pages per tank) <br /> Page 2 of 7 <br /> TYPE OF ACTION ❑ I NEW SITE PERMIT ❑ 4 AAIE`DED PERMIT ❑ 5 CHANGE OF NFOR ATION ❑6 TEMPORARY SITE CLOSURE <br /> (Check only item only) ❑7 PERMANENTLY CLOSED ON SITE <br /> (Specify reason-for local use only) (Specify reason-for local use only) ❑8 TANK REMOVED 430 <br /> ❑3 RENEWAL PERMIT <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: 1 <br /> STOCKTON USD-CORP YARD 3 �FA000�4016 <br /> 431 <br /> LOCATION WITHIN SITE(Optiomq <br /> M2_ �� ��wn� PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 4S2 TANK iv1.�L\-UFACTURER 433 COMPARTMENTALIZED TANK ❑Yes o 434 <br /> 10.00 MODERN WELDING If•Yes'.completeone page rmach comparnneru <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 20,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 418 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1.MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED E] S.JET FUEL <br /> (Ifnurkedcomplete PeoolaonType) ❑ Ib.PREMIUM UNLEADED' ® 3.DIESEL ❑6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑ 4.HAZARDOUS WASTE <br /> (Includes Used 00) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 44 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95 UNKNOWN <br /> ®2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ® 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ��❑....,,//3.FIBERGLASS/PLASTIC ❑ S.CONCRETE El 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL 4.STEEL CLAD W/FIBERGLASS [-] 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ t0.COATED STEEL ❑99.OTHER <br /> ❑ 5.CONCRETE <br /> 447 <br /> TANK INTERIOR LNNG ❑ 1.RUBBER LINED ❑3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED <br /> OR COATING ❑99.OTHER <br /> (Check one item only) ❑2 ALKYD LINING ❑4 PHENOLIC LINING ® 6 UNLINED (For local use only) <br /> 449 <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For foal use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE Occal use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Checkall that apply) X I SPILL CONTAINMENT 1996 ❑ I ALARM Xv3 FILL TUBE SHUT OFF VALVE <br /> flSt`[�2 DROP TUBE ❑ 2 BALL FLOAT ❑4 EXEMPT <br /> 3 STRIKER PLATE <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> IF SINGLE WALL TANK(Check all that apply) (Check one item only) <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ <br /> 6 VADOSE ZONE E] I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑ 7 GROUNDWATER X2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ STANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERTMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 4`7 <br /> gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.