Laserfiche WebLink
Quarterly Groundwater Monitoring Report BSK Job No P92219 3 <br /> October 1994 Novemberd 15, 1994 <br /> Van Den Bergh Foods Page 2 <br /> Stockton Facility <br /> In February of 1993, BSK drilled and sampled four soil borings to depths of 74 feet below the <br /> ' ground surface Results of the analysis of the soil samples from the four borings indicate that <br /> Petroleum hydrocarbons have not impacted soil beyond a radius of 35 feet from the former <br /> underground tank location Refer to BSK/Remediation Services, Soil Investigation and Quarterly <br /> ' Groundwater Sampling Report, April 2, 1993 for additional data and information <br /> ' Groundwater monitoring well MW-4 screened between 75 and 95 feet below the ground surface <br /> has been sampled on a quarterly basis since October 1992 <br />' In December of 1993, BSK installed two additional groundwater Monitoring Wells MW-5 and <br /> MW-6 Monitoring Wells MW-5 and MW-6 are screened between 70 and 90 feet below the <br /> ground surface <br /> OCTOBER 1994 MONITORING EVENT <br /> Groundwater Sampling Method <br /> Pnor to sampling on October 20, 1994, the depth to water in Monitoring Wells MW-4, MW-5 <br /> and MW-6 was measured utilizing an electric sounding tape The top of the groundwater surface <br /> in the well and the bottom of the well were sampled for visual observations using a clear acrylic <br /> bailer The collected groundwater sample was examined for the presence of odors and <br />' indications of petroleum product The well was then purged of at least four well volumes with <br /> a submersible pump Parameters for pH, electric conductivity, and temperature were measured <br /> after removal of each well volume Consistency of these measured properties indicated that fresh <br /> water was being drawn from the aquifer A groundwater sampling Iog was maintained for each <br /> well (refer to Well Field Logs) The groundwater removed during purging was placed into a <br /> 55-gallon DOT 17 E/H drum and labeled <br /> The groundwater was sampled with a Teflon" oint source bailer The samples were <br /> p p placed into <br /> an appropriate sample container with preservatives added and labeled The samples were stored <br /> in an cooler with ice and shipped to the BSK State-certified Analytical Laboratories in Fresno <br /> for chemical testing <br />' Analytical Testing <br />' Chemical analyses were performed on the samples for Total Petroleum Hydrocarbons as Diesel <br /> (TPH-D) by Method DHS GC/FID and Benzene, Toluene, Ethylbenzene, Xylenes (BTEX) by <br /> EPA Method 5030 and 602M <br /> tA summary of the analytical results from this sampling event and previous samplings is presented <br /> in Table I The Chain-of-Custody Record, Analytical Laboratory Data Sheets, and the Level 11 <br /> QC Summary are attached <br /> •ssociates <br />