ARCHIVED REPORTS_XR0008914
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
1400
>
3500 - Local Oversight Program
>
PR0545129
>
ARCHIVED REPORTS_XR0008914
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2020 10:39:19 PM
Creation date
1/7/2020 8:55:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008914
RECORD_ID
PR0545129
PE
3528
FACILITY_ID
FA0006171
FACILITY_NAME
Mizkan America, Inc.
STREET_NUMBER
1400
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205-3743
APN
14115002
CURRENT_STATUS
02
SITE_LOCATION
1400 E WATERLOO RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.0 Summary of Findings <br /> 3.1 Site Hydrogeology <br /> The well casing elevations were surveyed relative to an arbitrary bench mark at the site that <br /> was set to 100 00 feet The water table measured on August 9, 1995 was between 31 98 feet <br /> and 34 52 feet (corresponding to depths between 63 82 feet and 66 30 feet) A summary of <br /> groundwater elevation data is provided in Table 1 A potentiometric surface map for the site <br /> (Figure 2) indicates that the groundwater flows roughly to the north at a gradient between <br /> 0 013 and 0 023 ft/ft <br /> r3.2 Groundwater Quality Data <br /> Groundwater samples were collected from three monitoring wells (MW-4, MW-5, and MW- <br /> 6) Groundwater from MW-5 and MW-6 yielded TPH as diesel at concentrations of 84 <br /> micrograms per liter (µg11) and 210 µg11 respectively None of the samples yielded <br /> concentrations of TPH as gasoline or BTEX above the method detected limits. No detectable <br /> concentrations of the target analytes were identified in the quality control sample collected <br /> The quality control report from the laboratory was also determined to be acceptable <br /> Table 2 provides a summary of the groundwater analytical results The Certified laboratory <br /> results are provided in Appendix C <br /> MZ/09-20-95/VDBF/95-0027 NBR 3-1 <br />