Laserfiche WebLink
VI. SHIPPING INFORMATION Profile#: Pending Approv <br /> DOT Hazardous Material: Yes ER Guide#: 128 <br /> Proper Shipping Name: Combustible Liquid,NOS(Diesel Fuel Additive) <br /> Hazard Class and Division:Combustible Liquid UN or NA: NA1993 Packaging Group:III <br /> RQ: No If Yes: Addl.Info: <br /> USEPA HAZARDOUS WASTE: Ne <br /> 213 <br /> Waste I.D. NonRCRA <br /> Numbers: <br /> VII.INDICATE IF THIS WASTE CONTAINS ANY OF THE FOLLOWING CHARACTERISTICS as defined by 40 CFR 261.24. <br /> Check only if waste exceeds regulatory threshold levels and include analytical date if available. <br /> Regulatory TCLP Total Know Regulatory TCLP Total Know <br /> Coustimem level PPM PPM PPM ledge Constituent level PPM PPM PPM ledge <br /> D004 Arsenic 5,0 D024 m-Cresol 200.0 <br /> D005 Barium 100.0 D025 p-Cresol 200.0 <br /> D006 Cadmium 1.0 D026 Cresol 200.0 <br /> D007 Chromium 5.0 D027 1,4,Dichlorobenzene 7.5 <br /> D008 Lead 5.0 D028 1,2,Dichloroethane 0.5 <br /> D009 Mercury 0,2 D029 1,1 Dichlomethylene 0,7 <br /> D010 Selenium 1.0 D030 2,4 Dmitrotoluene 0.13 <br /> Doll Silver 5.0 D031 Heptachlor 0.008 <br /> D012 Endrin 0.02 D032 Hexachlorobenzene 0.13 <br /> D013 Lindane 0,4 D033 Hexachlorobutadime 0.5 <br /> D014 Methoxychlor 10,0 D034 Hexachloroethane 3.0 <br /> D015 Toxaphene 0.5 D035 Methyl Ethyl Ketone 200.0 <br /> D016 2,4 Dichlorophenoxyacetic acid 10.0 D036 Nitrobenzene 2.0 <br /> D017 2,4,5 TP Silvex 1,0 D037 Pentachlorophenol 100.0 <br /> DO 18 Benzene 0.5 D038 Pyridine 5.0 <br /> D019 Carbon Tetrachloride 0,5 D039 Tetrachloroethylene 0,7 <br /> D020 Chlordane 0.03 D040 Trichloroethylene 0.5 <br /> D021 Chlombenzene 100.0 D041 2,4,5 Trichlorophenol 400.0 <br /> D022 Chloroform 6.0 D042 2,4,6 Trichlorophenol 2.0 <br /> D023 o-Cresol 200.0 D043 Vinyl Chloride 0.2 <br /> VIII. Benzene Waste Operations NESHAP Generator Certification. Complete only if DO 18 and/orU019 <br /> annear in section 6(shinning information). <br /> I. Is this waste generated by an industry with any of the foflowing SIC Codes:2911,2800-2899,3312 or 4953? N/A <br /> 2. Does this stream have Benzene concentration of l0ppm or more? N/A <br /> 3. Does this stream contain greater than 10%moisture? 1 r <br /> 4. Is this company's Total Annual Benzene(TAB)of I OMg or greater per year? N/A <br /> 5. Is NESHAP form required? NSA <br /> AUTHORIZATION TO CORRECT WASTE MATERIAL PROFILE SHEET: In the event Rineco determines that it is necessary to make corrections on <br /> this Waste Material Profile Sheet to make the information herin consistent with the results of the sample characterization and/or applicable federal and state <br /> statutes and regulations, Rineco will contact the Generator and receive oral authorization to make such corrections. <br /> GENERATOR CERTIFICATION:THIS CERTIFICATION IS REQUIRED FOR EACH PROFILE. <br /> This above information is to be held confidential and is true and accurate to the best of my knowledge. <br /> Signature: Date: <br /> Print Name: Title <br /> 5/122008 10:02:25AM 2 <br />