Laserfiche WebLink
MONITORING AND REPORT._ -i PROGRAM NO. -2 - <br /> SUPPORT <br /> 2 -SUPPORT TERMINALS OPERATING PARTNERSHIP,LP <br /> BULK FUEL TERMINAL#29 <br /> STOCKTON,SAN JOAQUIN COUNTY <br /> - <br /> Quarterly Semi-annuallyZ Annually3 <br /> Wells OW-6D,OW-7A,OW-7B,OW-7C,OW-7D,OW-8A, PS/MW-17,PS/MW-19, PS/WC-4M <br /> OW-8B,OW-8C,PS/MW-14,PS/MW-15,PS/P-11,PS/P-12, PS/P-21,PS/WC-2M, <br /> PS/P-13,PS/WC-2S,PS/WC-3M,PS/WC-3S,ST/MW-1, PS/WC-4S <br /> ST/WC-lA, ST/WC-113,ST/WC-1C,UP/MW-1,New Wells <br /> 1 All wells shall be monitored quarterly for water levels and the presence and thickness of free product. <br /> 2 Wells shall be sampled semi-annually during the first and third quarters. <br /> 3 Wells shall be sampled annually during the third quarter. <br /> Constituents EPA Analytical Method Maximum Detection Limit(µg/l)° Sampling <br /> Frequencys <br /> Depth to groundwater --- --- Quarterly <br /> TPH as diesel 8015M 50 Quarterly <br /> TPH as diesel 8015M 50 Quarterly <br /> Benzene 8020 or 8260B 0.5 Quarterly <br /> Toluene 8020 or 8260B 0.5 Quarterly <br /> Ethylbenzene 8020 or 8260B 0.5 Quarterly <br /> Xylenes 8020 or 8260B 0.5 Quarterly <br /> MTBE6 8260B 0.5 Quarterly <br /> TBA6 8260B 5 Quarterly <br /> TAME' 8260B 0.5 Quarterly <br /> DIPE6 8260B 0.5 Quarterly <br /> ETBE' 8260B 0.5 Quarterly <br /> Ethano16 8260B 50 Quarterly <br /> Methano16 8260B 100 Quarterly <br /> 4 For nondetectable results. <br /> 5 Groundwater level measurements for all STTC and Support Terminals Operating Partnership,LP monitoring <br /> wells shall be collected on the same day and all groundwater monitoring samples shall be collected during the <br /> same week. <br /> 6 Fuel oxygenates,including MTBE TBA DIPE tertiary amyl methyl ether(TAME),ethyl tertiary 1but1 ether <br /> (ETBE),ethanol,and methanol shall be analyzed in all monitoring wells during two monitoring events in the first <br /> and third quarters. If results are nondetectable for fuel oxygenates for both sampling events,no further <br /> monitoring for oxygenates is required in that well. If a fuel oxygenate is detected,it shall be added to the <br /> quarterly monitoring program for the well in which it was detected. Monitoring wells that have already <br /> eliminated fuel oxygenate monitoring based on the previous MRP requirements do not need to be resampled for <br /> fuel oxygenates. <br /> REPORTING <br /> When reporting the data, the Discharger shall arrange the information in tabular form so that the <br /> date, the constituents, and the concentrations are readily discernible. The data shall be <br /> summarized in such a manner as to illustrate clearly the compliance with this Order. In addition, <br /> the Discharger shall notify the Board within 48 hours of any unscheduled shutdown of any soil <br /> vapor and/or groundwater extraction system. <br />