Laserfiche WebLink
DEL-TECH Geotechnical Support Services <br /> MONITORING WELL FIELD LOG <br /> 1996 <br /> PROJECT NAME VALLEY WHOLES]DRUGMPLE ANALYSIS PERFORMED , TPH-Gas, B T X E <br /> 1401 WEST FREMOMPLE TIME. 13 30 <br /> STOCKTON,CAMPLE CONTAINER(S). HCL PRESERVED <br /> 0 A.'s& 1 BAILER BLANK <br /> ALYSIS PERFORMED BY' FGL LABS <br /> CLIENT HUNTER&ASSOCIATESTE: 0312511996 <br /> PROJECT MANAGER BILL HUNTEMPLE LOCATION MW-1 <br /> AMPLER DON LIGHT START TIME. <br /> GROUNDWATER XXX ADOSE: OTHER'WELL HEAD P I D READING 146 0 PPM <br /> CASING ELEVATION. FEET MSL CASING DIAMETER 2 INCH <br /> DEPTH TO WATER 6 78 FEET CALCULATED CASING VOLUME 3 00 GAL <br /> DEPTH OF WELL-25 20 FEET TOTAL VOLUME PURGED. 12 0 GAL <br /> TIME VOLUME pH E.0 TEMP 0 R.P COLOR OTHER <br /> gallons units Umbos/cm Degrees C Molts Visual <br /> 0 71 1919 226 NIA TURBID GREY <br /> 30 70 1794 226 LT TURBID GAS ODOR <br /> 60 71 1690 228 11 " <br /> 90 71 1662 228 " CLEAR " <br /> 120 71 1638 227 " <br /> PURGE METHOD CENTRIFUGAL PUMP <br /> SAMPLE METHOD 3'STAINLESS STEEL BAILER <br /> DEPTH TO WATER AFTER PURGE: DEPTH TO WATER AT SAMPLE TIME, 6 84' <br /> WELL INTEGRITY, CAP AND SEAL ARE SECURE, LOCK IS INSTALLED <br /> REMARKS GOOD RECHARGE <br /> WEATHER CLOUDY SKIES <br /> QUALITY CONTROL. ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH STEAM CLEANER&ALCONOX <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES <br /> WELL LOCATION' EASTERN <br /> CONTAINMENT* POLY DRUMS <br /> INSTRUMENTATION. OR10N pH/TEMPERATURE METER 2 POINT pH CALIBRATION (4 0 &7 0) <br /> ORION CONDUCTIVITY METER <br /> ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 580B PHOTO IONIZATION DETECTOR <br /> hFR 0 4 IK6 <br />