Laserfiche WebLink
WORKPLAN <br /> FOR <br /> INSTALLATION OF ONE <br /> GROUNDWATER MONITORING WELL, <br /> ARCO FACH,YTY 5450,STOCKTON, CALIFORNIA <br /> This work plan has been prepared in accordance with Work Authorisation Number 20101-00 by <br /> Brown and Caldwell on behalf of ARCO Products Company (ARCO) for ARCO Facility 5450 ARCO <br /> Facility 5450 is located at 1617 East Fremont Street, Stockton, California (Figure 1) The work plan will <br /> be submitted to ARCO and the San Joaquin County Public Health Services, Environmental Health <br /> Division, (County) The County Site Code for this site is 505663 Before commencing work, all <br /> necessary permits will be acquired and approval of the work plan will be obtained from the County <br /> The proposed work is the installation of one groundwater monitoring well (MW-1) near the <br /> western end edge of the southwest pump island (product dispenser 1 and 2) Figure 2 presents the <br /> proposed location of monitoring well MW-1 The purpose of installing a well in this location is to <br /> determine if groundwater has been impacted by hydrocarbons in the area where hydrocarbon impacted soil <br /> was removed during the fiber-trench replacement in 1995 This investigation was requested by the <br /> County in a letter dated May 6, 1996 A copy of the May 6, 1996 County letter is included with this work <br /> plan as Appendix A <br /> The Site Safety and Health Plan (SSHP) prepared from a master SSHP for California-based <br /> ARCO facilities with site specific information, dated December 20, 1994, will be followed and retained <br /> on-site during the field work. <br /> This work plan describes the methods to be used in the field during drilling, soil sampling This <br /> plan proposes a project schedule for work at the site and the timely submittal of a site summary report to <br /> the County after the completion of this work <br /> SITE BACKGROUND <br /> ARCO Facility 5450 is an operating retail gasoline filling station In October 1995, ARCO <br /> replaced the single-wall product line and fiber trench system with double-wall fiberglass product <br /> lines Hydrocarbons were identified in the soil beneath the product dispensers 1 and 2 during the <br /> fiber trench replacement Approximately 35 cubic yards (in place) of soil were removed from the <br /> affected area and a sample was collected from the base of the excavation (approximately l I feet <br /> below grade) Minor hydrocarbons were identified in the soil at the base of the excavation <br /> Groundwater was not encountered during the excavation <br /> This report was prepared in accordance with the standards of the environmental consulting industry at the time it was <br /> prepared It should not berthed upon by parties other than those for whom it was prepared, and then only to the extent of <br /> the scope of work which was authorized This report does not guarantee that no additional environmental contamination <br /> beyond that described in this report Busts at the site <br /> 24MR£PORTS%WK,PL1 DOC <br /> I <br />