Laserfiche WebLink
San Joaquin County DIRECTOR <br /> Po i N Donna Heran, REFS <br /> �0z ,'; .Co Environmental Health Department <br /> ._ ASSISTANT DIRECTOR <br /> r. ` 600 East Main Street Laurie Cotulla, REHS <br /> Stockton , California 95202-3029 PROGRAM COORDINATORS <br /> - Mike Huggins, REHS, RDI <br /> cq . • ' ' P • s ov.oe <br /> Margaret Lagorio, REHS <br /> Website: www <br /> 18 r / hd g Robert McClellon , REHS <br /> Phone: (209) 468-3420 Jeff Carruesco , REHS, RDI <br /> Fax : (209) 464-0138 Kasey Foley, REHS <br /> April 1 , 2009 <br /> Foppiano Investments <br /> Ernest Foppiano <br /> 5313 Knox Drive <br /> Linden , CA 95236 <br /> Subject: Stockton City Taxi Service Site Code : 1117 <br /> 2085 Fremont Street <br /> Stockton , CA 95205 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed Ozone <br /> Bench-Scale Treatability Study (Study), dated February 26 , 2009 , submitted on your behalf <br /> by ATC Associates Inc. (ATC) and has the following comments. <br /> The Study documents the results of an ozone infusion bench scale test performed on soil <br /> and groundwater samples collected from your site . The results of the bench scale test <br /> indicate that while ozone infusion would be a very effective remedial method for destruction <br /> of the petroleum hydrocarbon contamination remaining at your site , it would also produce <br /> unwanted secondary byproducts of hexavalent chromium and bromate . Attenuation tests <br /> indicated the bromate would naturally attenuate in both the treatment area and downgradient <br /> of the treatment area, but the hexavalent chromium may not readily attenuate back to <br /> trivalent chromium in the treatment area, though it did attenuate downgradient of the <br /> treatment area . <br /> In the Study, ATC proposes to conduct an insitu ozone infusion pilot test per the Pilot Test <br /> Work Plan dated May 8, 2008. However, in correspondence dated July 1 , 2008 , the EHD did <br /> not approve the pilot test as proposed because a bench scale test for ozone infusion had not <br /> been completed . <br /> Please proceed with submittal of a work plan to conduct an insitu pilot test for ozone infusion . <br /> Address in the work plan the following points: <br /> 1 . Installation of infusion points; the EHD recommends a limited number of points to <br /> conduct a test, located near the former underground storage tank pit (UST). This <br /> would allow for monitoring of the hexavalent chromium downgradient of the test <br /> treatment area without going offsite. <br /> 2. In the May 8 , 2008 work plan the proposed screen interval depths of the sparge <br /> points was 60-65 feet below surface grade (bsg ) and 80-85 feet bsg , but there are <br /> no monitoring wells set at total depth 85 feet bsg . The middle depth monitoring <br /> wells at your site which are impacted with petroleum hydrocarbons have screen <br /> intervals set from 85-90 feet bsg . The ozone sparge points should be set in this <br /> same water bearing unit. <br />