Laserfiche WebLink
S , R E Scale <br /> ET I <br /> 0 15 30 60 Feet <br /> 1 Inch=30 Feet <br /> S-2 <br /> .2728 <br /> (ND) ' <br /> (ND) ` <br /> w l <br /> W Canopy <br /> ' <br /> ---- -- _-- _______ Station Building and <br /> Lube Bays <br /> Waste Oil Tank S-3 <br /> ( 61) <br /> (N0(ND) <br /> 0.0 Former UST's <br /> EXPLANATION <br /> M Dispenser Islands O <br /> 1.4 I 1 O Groundwater Monitoring Well <br /> F-+ ' Canopy <br /> W ( ° O Soil Boring <br /> i ,I UST's- y- �` p° -2717 Ground water elevation in feet <br /> u uu u n O <br /> (0 61) Benzene concentrations in ppb <br /> u siu u <br /> u u ii iE ° <br /> 11 11 °° (ND) MTBE Concentrations in ppb <br /> 4k� Ilh, Dispenser Islands a I Ground water elevation contour in feet <br /> N referenced to mean sea level(MSL) <br /> Planter i r— Arrows indicate approximate ground <br /> N3 � <br /> S-1 / water flow direction <br /> S -27 22 Approximate hydraulic gradient=0 001 <br /> ------ -- (5300) <br /> �--- ---------- ---- - (G500) - - Notes <br /> - - Depth to groundwater was guaged on <br /> 23-Nov-98 <br /> FREMONT STREET T <br /> PLATE GROUND WATER CONTOUR/CHEMICAL CONCENTRATION MAP CAMBRIA <br /> 2 Shell-branded Service Station <br /> 2494 Fremont Street 240-0797 <br /> Stockton California <br /> Drawn by JN Date I I Jan-99 Approved By Date ),12. Sf <br />