Laserfiche WebLink
3.11 The primary tank shall be stabilized from lateral movement within the enclosure by <br /> placement of four (4) lateral supports, one at each corner of the primary tank, welded to the <br /> base plate of the enclosure. <br /> 4.0 CONTROL ASSEMBLIES: <br /> 4.1 The control assemblies shall be installed on top of the primary tank, enclosed totally within <br /> the environmental containment cabinet and tested at the factory before shipment. <br /> 4.2 USED OIL COLLECTION SYSTEM <br /> 4.2.1 PUMP ASSEMBLY: The pump assembly consists of a 1" UL Listed air operated <br /> double diaphragm suction pump with a capacity of 10-15 gpm at 50 psi. <br /> 4.2.2 AUTOMATIC OVERFILL VALVE ASSEMBLY: The automatic overfill valve assembly <br /> consists of an air operated valve that is preset at the factory to stop the air flow to the <br /> suction pump when the liquid level in the storage tank reaches 95% of it's capacity. <br /> This assembly also includes an air filter/regulator, pressure gauge, and flexible air <br /> supply hose to connect the valve to the 112" coupler and air pump. <br /> 4.2.3 AUDIBLE ALARM: The audible alarm is incorporated within the automatic overfill <br /> valve assembly, and engages at the 95% capacity level. <br /> 4.2.4 PRODUCT INTAKE LINE: The product intake line consists of a UL Listed 314" by 8' <br /> hardwall suction hose with in-line strainer, one each 314" female quick coupler and <br /> 314" male quick coupler, and hose hanger bracket. <br /> 4.2.5 PRODUCT REMOVAL: The product contained inside the primary tank shall be <br /> removed through a 2" cam and groove fitting with locking cap assembly and 2" suction <br /> tube. <br /> 4.3 NEW OIL DISPENSING SYSTEM <br /> 4.3.1 DISPENSING PUMP ASSEMBLY: The pump assembly consists of a 1" UL Listed air <br /> operated 5:1 piston pump. This assembly also includes an air filter/regulator, pressure <br /> gauge, and flexible air supply hose to connect the valve to the 112" coupler and air <br /> pump. <br /> 4.3.2 PRODUCT FILL: The product fill consists of a 2"fill cap. <br /> 4.4 NORMAL VENTING: The working vent consists of a 2" mushroom vent cap and rubber <br /> grommet for sealing penetration through the secondary tank. <br /> 4.5 EMERGENCY VENT: The emergency vent consists of a 4"or 6"emergency relief device. <br /> 4.6 PRODUCT LEVEL GAUGE: The sight level gauge is mechanical, reading in inches. A tank <br /> conversion chart shall be provided to convert the inch readings into gallons. <br /> 4.7 ANNULAR SPACE LEAK DETECTOR: An OPTIONAL leak gauge can be installed. <br /> 5.0 INSTALLATION AND OPERATING INSTRUCTIONS: <br /> 5.1 Installation and Operating Manual and Instructions shall be provided for each system. <br /> 3 <br /> March 2009 • ®Copyright 2009 • Containment Solutions,Inc. • All Rights Reserved • Pub.No.KT14501 B <br />