Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3505
>
2300 - Underground Storage Tank Program
>
PR0231848
>
COMPLIANCE INFO_2006 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:33:46 PM
Creation date
1/10/2020 1:36:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2018
RECORD_ID
PR0231848
PE
2361
FACILITY_ID
FA0002052
FACILITY_NAME
NuStar Terminals Operations Partnership L.P.
STREET_NUMBER
3505
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16203004
CURRENT_STATUS
01
SITE_LOCATION
3505 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sj oc ov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Nustar Ener LP Facility 3505 Nav Dr., Stockton Inspection May 30, 2012 <br /> Name: Energy Address: y Date: <br /> VIOLATIONS <br /> # I Ci I C2 M I Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation,C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> ROUTINE ANNUAL INSPECTION & MONITORING SYSTEM CERTIFICATION <br /> Class II violations: (108, 206) <br /> 108. Secondary containment testing was last performed on February 20, 2009 and was completed on <br /> May 24, 2012, three months past due. Secondary containment testing is required once every 36 <br /> months. Take all necessary precautions to ensure testing is performed in a timely manner. <br /> 204. The designated operator failed to check and note the correct test dates for the secondary <br /> containment testing and monitoring system certification on the designated operator monthly inspection <br /> reports. The secondary containment testing was due in February 2012; the March, April, and May 2012 <br /> designated operator reports all indicate that testing was completed within the required time frame. <br /> During the monthly inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. <br /> Complete & submit a copy of the Return to Compliance Certification form to the EHD by June 30, 2012, <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> Provided: <br /> - Schedule of FREE classes <br /> - Return to Compliance Certification form <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPE ON AT ANY TIME EHD'S CURRENT HOURLY RATE. <br /> inspector:_- <br /> ceived By: Title: <br /> r^ <br /> EHD 23-02 Ray 04/1942 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.