Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.orQ/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> NUSTAR ENERGY LP Jun 25, 2010 <br /> Facility address: UST!1 4 6 <br /> 3505 NAVY DR, STOCKTON Product EXEMPT WASTE <br /> Facility contact: TMe: Phone: <br /> DAN THOMAS TERM MANAGER 943-5662 <br /> Monitoring panel: Piping system: OwrtlN prevention: Violations: <br /> Pressurized Suction®Gravity Mechanical M1-RDetect❑M3-Both <br /> INCON TS-1001 Audible/visual M2-RPrev <br /> Inspection type: Designated operator. ICC exp.dab: <br /> ©Routine ❑Monitoring Certification installation ❑Other DAN MCI LRATH 02/07/11 <br /> On site Service Technician's name: ICC exp.date: Manutacturer's training: <br /> ZANE NIMMO 06/20/11 INCON=05/21/11 <br /> N Code Section HSC=CA Health & SafetyCode; CCR=CA`Cd VIOLATIONS <br /> Res lations; V=Violation: RV=Re eat Violation V V <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment: (a)test not performed, (e)test report not submitted within 30 days, (f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD) at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711(b)&(c) Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) X <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program (Monitoring &Response Plans)is not current ora proved by the EHD <br /> 6 CCR 2712(i) Monitoring and/or response plan is not onsite <br /> Maintenance&monitoring records not maintained 3 years, cathodic protection records for 6'/z (mi) <br /> years, written performance claims pertaining to release detection systems for 5 years, or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results <br /> of any visual observations, (4) results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction ninir re-Janus 1, 1984 not performed (Mt) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST/piping (Mt) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (Mt) <br /> containment <br /> 13 CCR 2636(0(1) Failed to maintain a continuous monitoring system for underground piping& UDCs that activates (Mt) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631(a) Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mill <br /> 18 CCR 2635(b)(1) Spill container not installed, failed to contain a minimum capacity of five gallons, or failed to (Al2) <br /> provide a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (11I2) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (M <br /> 21 HSC 25291(e) Water in 21 containment not removed, analyzed&properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (Mt) <br /> 22 CCR 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours, or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 5(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EH spec! Re d by. Titl /1 <br /> EHD 23-02-002 REV 04/08/10 Page 1 UST OFFICIAL INSPECTION REPORT <br />