Monitoring System Certification- Page 2 of 3 <br /> RECt.Y .� <br /> Site Address: 3505 Navy Dr. Date of 1'esting/Servicing: 5194114 <br /> JUN Y Y 2014 <br /> U. Results of Testing/Servicing <br /> ENVIRpNMEN�- <br /> Software Version Installed. 4.003 ��,, ',,`A,- � <br /> �EpAR�" E�4-r <br /> Com lete the following checklist: <br /> a Yes ❑ No* Is the audible alarm operational? <br /> a Yes 0 No* Is the visual alarm operational? <br /> a Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Do Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> 0 Yes 0 No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> ® N/A operational? <br /> 0 Yes 0 No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> a N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes 0 No <br /> ❑ Yes 0 No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> a N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill paints)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 0 % <br /> ❑ Yes* a No Was any monitoring equipment replaced?If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> Cl Yes* a No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> 0 Product;0 Water. If yes,describe causes in Section E,below. <br /> M Yes 0 No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if a licable. <br /> a Yes 0 No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Tank is monitored by 2nd Piping Sump Sensor(ALS)-Tested&Passed. <br />