Laserfiche WebLink
r <br /> Ms.Lori Duncan <br /> November 15,2011 <br /> RE: 2911 E.Fremont St,Stockton,CA <br /> Page 8 of 14 <br /> comparing the various ESLs established by RWQCB SF Bay,site concentrations are well below the ESLs <br /> based upon direct exposure, which is not an exposure pathway at the site because contaminated soils <br /> remaining exist at depths greater than 15 feet and are overlain by concrete and asphalt. In addition, <br /> groundwater sampling at the site detected only very low levels of PCE, but no residual gasoline <br /> consitituents,which suggests that native clay and silt zones present between the residual contamination <br /> and the known water table at the site act as an effective barrier to migration of contaminants downward to <br /> the water table. <br /> INDOOR AIR SAMPLING AND RISK EVALUATION <br /> Although direct contact with employees is not an exposure pathway and groundwater sampling has shown <br /> that groundwater beneath the former clarifier has not been significantly impacted, the residual soil <br /> contamination remaining beneath the former clarifier could pose a potential vapor intrusion concern. To <br /> investigate the potential vapor intrusion risk,L&P personnel collected air samples both inside and outside <br /> the warehouse building that housed the former clarifier. The samples were collected in general <br /> accordance with guidelines prepared by the California Environmental Protection Agency,Department of <br /> Toxic Substance Control, (CaVEPA-DTSC, October 2011). <br /> Pre-Sampling Site Visit and Interviews <br /> Prior to collecting indoor and outdoor air samples,L&P conducted a site visit to determine the pattern of <br /> use for the area in question(Warehouse#2). L&P conducted informal interviews with staff including the <br /> operations manager,dispatch manager and several employees working outside near the warehouse. Site <br /> personnel indicated that Warehouse#2 is used as storage of merchandise and the doors typically remain <br /> closed during site operations. <br /> The warehouse was fairly empty during the site visit. There were no visible chemicals stored within the <br /> warehouse. Activity outside the warehouse includes vehicle fueling (above ground storage tanks in a <br /> covered fueling area) and equipment loading. The yard office is located 80 feet east of the warehouse. <br /> The predominant wind direction is from the northwest. Upwind properties include residences and a <br /> school. <br /> Air Sampling and Analysis <br /> The air samples were collected on October 12,2011 and analyzed by the laboratory on October 17,2011. <br /> The indoor and ambient air samples were collected into 6-liter Summa Canisters using a flow controller set <br /> by the laboratory to collect time-weighted samples over an 8-hour period. One indoor air sample(602-IAI) <br /> was collected immediately over the excavated area,one indoor air sample(602-IA2)was collected at the rear <br /> of the warehouse,one ambient air sample(602-AA 1)was collected next to the yard office(approximately 80 <br /> feet east of the excavated area),and one ambient air sample(602-AA2)was collected at the eastern property <br /> boundary. A slight wind originated from the northwest. Although no chemicals were stored in the warehouse <br /> 10759-EXC SUMMARY LTR <br />