My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4100
>
3500 - Local Oversight Program
>
PR0545177
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 5:37:29 PM
Creation date
1/13/2020 4:06:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545177
PE
3528
FACILITY_ID
FA0002123
FACILITY_NAME
GREWALS GAS & LIQUOR*
STREET_NUMBER
4100
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14333046
CURRENT_STATUS
02
SITE_LOCATION
4100 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
246
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ t i <br /> 1 <br /> Mr. Robert Trommer Page 5 of 7 I <br /> Comments on CUF Site Closure Recommendations for Various Sites March 3, 2010 <br /> With a favorable report, the EHD should be able to start closure process and estimates,final <br /> closure will be achieved in six to nine months. <br /> Claim No. 14118 - 444 Mossdale Road, Lathrop <br /> Closure for this site is delayed'. due to problems with the vapor intrusion evaluation. The <br /> consultant utilized soil data for the evaluation ignoring some highly impacted samples and <br /> overestimating the distance of the samples used from the existing building. No justification for a <br /> 'safe' distance between impacted soil and an existing building was .provided. As stated above <br /> for another site, the EHD would like to close this site and believes it should be closed, but as <br /> .vapor intrusion has been identified at the State level as a potential health issue that must be <br /> addressed before closing a site, the EHD has been attempting to exercise due diligence by <br /> acquiring defensible data that demonstrates that the health risk posed by potential vapor <br /> intrusion from: residual contamination is at or below an acceptable level. The EHD expects this <br /> site may be closed in three to six months. <br /> Claim No. 14328 - 1501 W. Charter-Way <br /> The closure :process for this site has been initiated, and notification documents for the <br /> CVRWQCB are in preparation. The site monitoring wells will need to be destroyed. The EHD <br /> estimates three to six months will be required to. complete the closure process for this site. <br /> Claim No. 14349 - 517 W. Fremont Street, Stockton <br /> In the 2008 CUF letter, the CUF recommended initiation of groundwater remediation. In 2009, <br /> the CUF recommend site closure although no remediation had been conducted. The EHD had <br /> directed implementation of groundwater remediation. and set several dates that were not <br /> complied with. To date, there 'las been no attempt at active remediation. The plume of <br /> impacted groundwater on the, site is delineated, but the EHD believes the contaminant <br /> concentration; in well MW-3 to be too high for closure consideration without remediation. <br /> Benzene was present in MW-1 in June 2009 at 4,600 pg/L, TPHg was present at 23,000 pg/L, <br /> and 1,2-dichloroethan (1,2-DCA),at 63 lag/L. The EHD has approved a work plan to install and <br /> test a soil vapor extraction (SVE) well and an in-situ air sparge (IAS) well. As no remediation <br /> has yet been attempted on this site, the EHD believes it would be very beneficial to make such <br /> an attempt and reduce the contaminant mass and accelerate the return to applicable water <br /> quality goals. <br /> Claim No. 14353 - 3400 Newton Road Stockton <br /> xr <br /> This site has an approved work plan(approved by EHD letter dated July 29, 2009) to conduct a <br /> soil vapor extraction test on monitoring wells MW-1. and MW-8, which the EHD expects will <br /> address soil underlying the former tank pit impacted by methyl tent-butyl ether (MTBE) at <br /> concentrations as high as 5.2 milligrams per kilogram (mg/Kg). Groundwater in MW-1 becomes <br /> impacted when groundwater elevation rises into the well and encounters impacted soil currently <br /> in the vadose zone. Groundwater in the surrounding wells is usually not impacted; however <br /> there is a domestic well on the site approximately 134 feet from the former tank pit. The EHD <br /> believes for very little expense the MTBE mass in soil can be reduced which will greatly reduce <br /> the probability that the on-site domestic well will become impacted during a period of high j <br /> groundwater elevation and the site is no longer monitored. <br /> On January 29, 2010, the CUF changed the priority class of the site from Class "C" to Class "B." <br /> The EHD anticipates that this will relieve the delay of work on this site and enable the test to be <br /> Comments on CUF Site Closure Recommendations 0310.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.