Laserfiche WebLink
Hazardous Waste Tank System September <br /> Final Written Assessment per CCR Title 22 <br /> Stockton Dodge.Stockton,CA 95212 20 5 .-OBVED <br /> DEC 21 2015 <br /> Volume calculation(s) <br /> ENVIRONMENTAL HEALTH <br /> The secondary containment for the waste oil tank is provided by the integral PERMITiSERVICES <br /> secondary containment. Secondary containment for the waste antifreeze tank is <br /> provided by a polyethylene beam of 400 gallons. The waste antifreeze tank's <br /> working volume is 193 gallons. The tanks, piping and pumps are under roof <br /> above a concrete pad and foundation. The twenty five year rain event does not <br /> apply since the tanks, piping and pumps are under roof. The secondary <br /> containment is inspected daily by the Stockton Dodge staff. The secondary <br /> containment is sufficient. <br /> Visual inspection of containment area: <br /> The containment for the piping and pumps were found to be dry with no evidence <br /> of leaks. Visual inspection of the secondary containment found it dry and the <br /> concrete around the secondary containment was dry with no evidence of leaks. <br /> Site Security: The waste oil and antifreeze tanks are within a fenced area. The <br /> fence is locked when unattended and is routinely patrolled by the Stockton Police <br /> department. <br /> Secondary Containment findings: The secondary containment system is of <br /> sufficient capacity and condition for the containment of releases from all s <br /> and ancillary equipment. Initials: <br /> Strandberg Associates 1(866) 388-0404 rwaterguy_[a)rwaterguy.com 25 <br />