Laserfiche WebLink
Stockton Dodge Chrysler Jeep Ram, Waste Antifreeze Tank, (Facility 11745), 22§CCR 66265.192,August <br /> 2018 <br /> 4.4 Serviceability <br /> 4.4.1 Tank Repair/Recommendations <br /> All repair work must be authorized by a Certified Inspector or an Engineer experienced in <br /> storage tank design, before commencement of the work by a repair organization. A <br /> Certified Inspector must designate inspection hold points required during the repair or <br /> alteration sequence and minimum documentation to be submitted upon job completion. <br /> The Certified Inspector may give prior general authorization for limited or routine repairs <br /> as long as a Certified Inspector is sure that the repairs will not require hydrostatic testing <br /> or do not require an engineering evaluation. <br /> All proposed design, work execution, materials,welding procedures, examination, and <br /> testing methods must be approved by a Certified Inspector or by an Engineer experienced <br /> in storage tank design. A Certified Inspector or an Engineer experienced in storage tank <br /> design shall approve all specified repair and alteration work at the designated hold points <br /> and after repairs and alterations have been completed in accordance with the <br /> requirements of API Standard 653. <br /> Recommendations to bring the tank into compliance with API Standard 653, along with <br /> additional recommendations,to bring the tank and other components into compliance <br /> with other Codes and Standards, have been identified in this report. Completion of these <br /> items is recommended to ensure successful long term service. All recommendations and <br /> repairs are at the discretion of the tank owner to re-categorize and/or determine if repairs <br /> are warranted and/or desired. <br /> 4.4.2 Structural Integrity <br /> The Waste Antifreeze tank is in compliance with the requirements of Title 22 § CCR <br /> 66265.192 for hazardous waste tank systems. This assessment is valid for a maximum of <br /> 5 years or upon any changes to the tank system. The next formal external inspection <br /> should be accomplished by a Professional Engineer prior to May 2023 in accordance with <br /> Title 22 § CCR 66265.192. <br /> 4.4.3 Routine Inspection <br /> Perform routine periodic visual inspections by owner/operator personnel knowledgeable <br /> of the storage facility operations,the tank, and the characteristics of the product stored. <br /> Perform routine daily visual inspections by owner/operator personnel knowledgeable of <br /> the storage facility operations,the tank, and the characteristics of the product stored; <br /> conduct in accordance with Title 22 § CCR 66265.192. <br /> 7 <br />