Laserfiche WebLink
' Table 5 <br /> RADIUS OF INFLUENCE DATA FOR SVE AT DPW-1 - 3113102 <br />' Barnes Trucking <br /> 1817 S Fresno Avenue <br />' Stockton, California <br />' Extraction Well DPW-1 <br /> Diameter 4 inches <br /> Screen Available 15 ft total(10'to 25'open by GWE @ 2 1 gpm) <br />' Vacuum at DPW-1 40 in w c <br /> Flowrate at DPW-1 8 5 cfm <br />' Observed vacuum at surround wells at induced vacuum of <br /> 40 in we on DPW-1 <br />' Observation Distance from DPW-1 Observed Vacuum <br /> Point I D feet) in w c) <br /> MW-513 10 007 <br />' MW-6 60 002 <br /> MW-1 72 000 <br /> MW-7 100 000 <br />' Note Effective remedial induced vacuum is generally accepted as 0 1 in w c <br /> The radius of influence for SVE at DPW-1 is assumed to be—6-8 feet because <br />' the closest well located 10 feet from DPW-1 only exhibited a vacuum of 0 07 in w c <br /> Observed vacuum at surrounding wells at other steps of induced vacuum on DPW-1 <br />' Observation Point Observed vacuum(in we) Observed vacuum(in w c) Observed vacuum(in we) Observed vacuum(in w c) <br /> 1 D DPW-1 @ 10 in w c DPW-1 @ 20 in w c DPW-1 @ 30 in we DPW-1 @ 50 in w c <br />' MW-513 004 006 004 005 <br /> MW-6 000 001 000 001 <br /> MW-1 002 000 000 000 <br />' MW-7 000 000 000 000 <br /> I <br /> I � <br />' Page I of 1 <br />