Laserfiche WebLink
' CLEARWATER GROUP <br />' Air Sparging, Soil Vapor Extraction, and <br /> Combined Air Sparging/Soil Vapor Extraction Pilot Tests Field Procedures <br />' Air Sparging Pilot Test <br /> The air spargmg test will be performed by applying air pressure to the sparging well The flow of air trom the <br /> sparge well will be monitored to determine it's extent and effect on the surrounding formation and ground water <br />' The test will be performed at different levels of applied air pressure The applied air pressure will be changed when <br /> the pressure influence in surrounding wells stabilizes The initial applied air pressure will be 10 psi- The applied <br /> air pressure will not exceed 45 psig, the PVC pressure lima The infected air pressure will not exceed 45 psi to <br /> provide a safety factor to prevent rupture of the well screen,and the flowrate will not exceed 60 cfm <br />' Air pressure will be applied to the spargmg well using a towable, engine-driven air compressor The comps essed an <br /> will be filtered to remove any water, particles, and compressor oil All above ground air pressurized piping will be <br /> metal or hose suitable to the application No plastic pipe will be used <br />' Prior to beginning the test,the following measurements will be made at the surrounding observation wells <br />' Depth to water will be measured to the nearest 0 01 foot with a Solinst electronic interface probe of <br /> equivalent <br /> • Dissolved oxygen(DO)content of the well water will be measured <br />' Hydrocarbon concentration in the air dust above the water level in the observation wells will be measured <br /> with a flame ionization detector or a photo-ionization detector <br />' The test will be run in steps, each step at a different infected air pressure During each step, the tollowin- <br /> parameters will be measured to monitor the surrounding formation and determine when flow through the ton matron <br /> has stabilized <br /> • The induced pressure on the surrounding wells will be measured by MagnehelicO gauges in inches of water <br /> • The infected air flowrate will be measured with a Kurz®Model 443 thermal anemometer, or equivalent <br /> IOnce the formation has stabilized,pressures will be increased and the next test step will begin After the final step <br /> test, the depth to water, dissolved oxygen content in the well water, and the oxygen and volatile content of the ait <br />' above the water in each observation well will be measured using the same instruments as above <br /> Soil Vapor Extraction Pilot Test <br /> Prior to performing the test, any necessary air permits shall be obtained and the test will be performed in accordance <br /> I with any requirements stated in the permit The test will be performed by applying a vacuum to an existing vapor <br /> monitoring or extraction well or a soil vapor probe with a vacuum pump to extract soil vapor The test will be iun <br /> at different applied vacuums until the vacuum influence in surrounding wells or points has stabilized of one pose <br /> volume has been extracted from the soil <br />' The following measurements will be made during the test for the different applied vacuums <br /> • Vacuum applied to the well will be measured with a vacuum gauge and adjusted with a bleeder valve on the <br /> vacuum side of the pump <br /> • Volatiles and oxygen content from the extraction well will be monitored during the test using a flame <br />' ionization detector or a photoionization detector <br /> • The vacuum influence in surrounding wells will be measured in inches of water (vacuum) with MagneheliA <br /> gauges, or equivalent <br /> I <br /> CLEARWATER GROUP ] REVISLD NtaN 8 2002 <br />