Laserfiche WebLink
U E046 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10207021 01 /08/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building # <br /> Pacific Bell Telephone Co . dba AT&T California <br /> Business Site Address City ZIP Code <br /> 907 Lincoln Rd . Stockton 95207 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> TAIT Environmental Services , Inc. (714) 560-8222 <br /> Mailing Address <br /> 11280 Trade Center Dr. , Rancho Cordova , CA 95742 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Craig Feezell <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 588098 18374133 07-03-2021 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> Veeder- Root A23508 06m2021 <br /> Ili . RESULTS OF TESTING / SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> ❑X <br /> Monitoring System Set-u X❑ Alarm History Report <br /> Was any monitoring equipment replaced ? <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below) <br /> Was damage , debris, or liquid found inside any secondary containment systems? <br /> (If "Yes, " describe what was found in section IV below) El N El <br /> Is all monitoring equipment operational per manufacturer's specifications ? <br /> (If "No, " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> "R r <br /> Er J <br /> JAN 2 4 2020 <br /> ENVIRONMENTAL HEALTH <br /> DEPAPTMENT <br /> i <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , Title 23 , Division 3, Chapter 16 , Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e. g . , manufacturers' checklists , monitoring system set-up , alarm history report, etc . ) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> 4: * 40 ❑ Check If Action Item (s) Are Present <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not Applicable <br />