My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/14/2021 1:42:41 PM
Creation date
1/17/2020 12:05:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95366
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action N Installation Test N Repair Test ❑Six Month Test ❑36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10184539 02/07/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Chevron 210997 <br /> Business Site Address City ZIP Code <br /> 1442 W. Colony Rd Ripon 95366 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification.) Phone# <br /> Nick Harvey (916)834 - 5099 Ext. <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 300345 A B C61/D40 HAZ 5115738 01/11/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> Tank ID:(By tank number,stored product,etc.) A 87 B 91 C D <br /> Tank Containment <br /> Tightness Test Result N Pass ❑Fail ❑ NA N Pass ❑ Fail ❑ NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result N Pass ❑Fail ❑ NA N Pass ❑Fail ❑NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result N Pass ❑ Fail ❑ NA N Pass ❑ Fail ❑NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail N NA ❑Pass ❑ Fail N NA ❑Pass ❑Fail ❑NA ❑ Pass ❑ Fail ❑NA <br /> Communication Test Result ❑ Pass ❑Fail N NA ❑ Pass ❑ Fail N NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑ Fail N NA ❑ Pass ❑Fail N NA ❑Pass ❑ Fail ❑ NA ❑Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑Pass ❑Fail N NA ❑ Pass ❑ Fail N NA ❑Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑Fail N NA ❑ Pass ❑ Fail N NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑Fail ❑ NA <br /> Communication Test Result ❑Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result N Pass ❑Fail ❑ NA N Pass ❑ Fail ❑ NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result N Pass ❑Fail ❑ NA N Pass ❑ Fail ❑ NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Vent/Transition Sump ID: a b C d <br /> Tightness Test Result ❑Pass ❑ Fail ❑ NA ❑ Pass ❑Fail ❑NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> UDC ID: 1 2 3 <br /> Tightness Test Result ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA N Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑Fail ❑NA ❑ Pass ❑ Fail ❑ NA ❑Pass [:]Fail ❑NA ❑ Pass ❑ Fail ❑NA <br /> All items marked"Fail"or"N/A"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,title 23, <br /> division 3,chapter 16,section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature �) � I <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground storage tank,ICC=International Code Council, <br /> NA=Not applicable,UDC=Under-dispenser containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.