Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection I] 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181669 6/ 11 /2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> QUICK SHOP # 1 <br /> Business Site Address City ZIP Code <br /> 2072 YOSEMITE AVE MANTECA 95337 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification) Phone # <br /> David Winkler (209 ) 744 - 0112 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 08- 1739 Ex . 3/31 /2020 8883059-UT 1 /29/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications) <br /> FF- EBW , PhikTite & EVR Phase 1 1009853708 Ex 11 /29/20 OPW 104-633 Ex 3- 14-2020 <br /> Emco #3207 Ex . 11 /16/20 ATG : VR : B34975 ATG : 2/8/20 INCON 1009853708 Ex. 11 /30/2020 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines (Specify): <br /> Used : REMOVED OPW DROP TUBES <br /> �I <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages 5 <br /> TANK ID : (By tank number, stored product, etc.) 87- 1 91 100 110 <br /> What is the tank inside diameter? (inches) 95 . 75 95 . 75 95 . 75 95 . 75 <br /> Is the fill piping secondarily contained? ❑ Yes ❑x No ❑ Yes ❑x No ❑ Yes ❑x No ❑ Yes ❑x No <br /> Is the vent piping secondarily contained? ❑ Yes 0 No ❑ Yes ❑x No ❑ Yes I] No ❑ Yes ❑x No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW <br /> 61 SO 61 SO 61 SO <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> ❑ <br /> (Check all that apply.) Restricts Flow El Restricts Flow El Restricts Flow El Restricts Flow <br /> ❑ A/V Alarm ❑ AN Alarm ❑ AN Alarm ❑ AIV Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes I] No ❑ Yes I] No ❑ Yes E No ❑ Yes 0 No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank) 84 . 5 84 . 5 85 . 5 85 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93 93 94 93 <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑x Yes D Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V) ElNo (Specify in V.) ElNo (Specify in V.) ElNo (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results IN Pass ❑ Fail ❑x Pass ❑ Fail Z Pass ❑ Fail X Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail' must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify thatthe overfill prevention equipmentwas inspected in accordancewith California Code of Regulations , Title 23 , <br /> Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intemational Code Council, AN = Audible and Usual <br />