My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
3500 - Local Oversight Program
>
PR0545195
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2020 11:57:15 AM
Creation date
1/23/2020 11:44:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0545195
PE
3528
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
02
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
227
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y ATC Associates Inc. <br /> .. v 1117 one Palm Avenue, Suite 201 <br /> v Modesto, California 95351 <br /> 209-579-2221 <br /> y ASS O C I ATE S I N C . fax: 209-579-2225 <br /> .r accurately represent adsorbed-phase petroleum concentrations, if present, due to the water <br /> component of the sample. r ,: .F 1, , _ wrs �- - J ve 7 <br /> bw <br /> Historically, elevated adsorbed TPHg was encountered in the shallow soils (six to ten feet bgs) <br /> beneath the site. The soil sampling proposed during this investigation will attempt to further <br /> bw define the vertical and lateral extent of TPHg(and BTEX, where applicable) both on-site and off- <br /> site. Figure 10 depicts the TPHg in soil isoconcentrations from six to ten feet bgs from data <br /> collected during previous subsurface investigations. Refer to Table 3, which is a summary of the <br /> soil analytical results. <br /> The monitoring wells will be constructed of 2-inch inside diameter, Schedule 40 PVC casing and <br /> tAW 0.010-inch slot screen PVC. `The wells will be installed to approximately 20 feet bgs with 15 <br /> feet of 0.010-inch slot screened PVC. A sand pack will be placed in the annulus of each well <br /> extending from the bottom of the well screen to approximately one foot above the top of the <br /> screen. Approximately one foot of bentonite will be placed on top of the sand pack and hydrated <br /> with potable water. The remaining annulus will be completed to surface with cement grout. To <br /> Wo protect the integrity of the wells, locking, watertight well plugs will be installed on each well and <br /> a watertight wellhead labeled "monitoring well" will be set in concrete over each well. The <br /> proposed monitoring well locations are shown on Figure 11. Refer to Attachment 1, which <br /> `„ depicts a typical groundwater Zone A monitoring well construction diagram. <br /> Zone B and Zone C Vertical Delineation <br /> r <br /> As previously indicated, a grab groundwater sample collected from CPT-2 at 41 feet bgs on <br /> October 14, 2004, i gated t resence of dissolved MTBE, BTEX, and TP at45��f <br /> bw concentrations of 2, µg/1�' .1 µg/l, 2IR µg/1, 0 µg/1, 2�D /S and 7,600 µg/l, " <br /> respectively. MTBE, BTEX, anS TPHg were detected in a grab groundwater sample collected <br /> from CPT-2 at a depth of 67 feet bgs at the following respective concentrations: 120 ttg/l, 2.7 <br /> y µg/1, <0.5 µg/1, 7.9 µg/l, 20 µg/1, and 300 µg/l. <br /> Two groundwater monitoring wells are proposed to be installed at the site to evaluate <br /> groundwater quality in Zone C. These wells will be installed adjacent to the USTs and MW7 to a <br /> depth of approximately 75 feet bgs. The monitoring wells will be installed inside conductor <br /> y casing extending to approximately 55 feet bgs in an effort to minimize potential vertical <br /> contaminant migration from shallower groundwater. The monitoring wells will be constructed of WWI' <br /> 2-inch inside diameter, Schedule 40 PVC casing and five feet of 0.010-inch slot screen PVC. A <br /> IBM sand pack will be placed in the annulus of each well extending from the bottom of the well <br /> screen to approximately three feet above the top of the screen. Approximately three feet of <br /> bentonite will be placed on top of the sand pack and hydrated with potable water. The remaining <br /> 6.0 annulus will be completed to surface with cement grout. To protect the integrity of the wells, <br /> 6.0 7 ATC Associates Inc. <br /> S:\Environmental\25847.0037\Work Plan additional vert-hor delineationTH2.doc <br /> y <br />
The URL can be used to link to this page
Your browser does not support the video tag.