Laserfiche WebLink
AM <br />. Site Safety Plan Working To Restore Nature <br /> Unocal Station No. 6981, Stockton, Califorrua <br /> i <br /> 10 to 25 percent then Continue monitoring <br /> of LEL with extreme caution as <br /> higher levels are <br /> encountered <br /> Greater than 25 then Explosion hazard <br /> percent of LEL Cease activities and <br /> vacate area immediately <br /> 1 <br /> * CGI readings in percent of lower explosive limit <br /> If an explosion potential is present onsite beyond 25 percent of the LEL then all RESNA' <br /> personnel and subcontractors must immediately withdraw from the site The hazard <br /> potential will be evaluated by RESNA' management and a plan of action will be assessed <br /> DECONTAMINATION PROCEDURES <br /> Drilling equipment and personal protective equipment will undergo gross decontamination <br /> 018 onsite This gross decontamination will include washing contaminated equipment with a <br /> trisodium phosphate (TSP) solution Steam-cleaning is an acceptable alternative <br /> EMERGENCY RESPONSE PROCEDURES <br /> r In the event of a fire, explosion, or property damage, the nearest RESNA Branch and the <br /> Administrative Office will be immediately notified. If necessary, local fire or response <br /> agencies will be called <br /> In the event of an accident resulting in physical injury, first aid will be administered and the <br /> inured worker will be transported to the nearest hospital or emergency medical clinic for <br /> 0 emergency treatment A physician's attention is required regardless of the severity of the <br /> injury- <br /> 0 <br /> 38032-935 14 <br />