Laserfiche WebLink
1 INTRODUCTION <br /> This report presents data collected during the fourth quarter 1995 monitoring period at the <br /> Pacific Gas and Electric Company (PG&E) Tracy Service Center, 502 East Grantline Road, in <br /> Tracy, California(see Figure 1). <br /> 2 GROUNDWATER GRADIENT AND DIRECTION <br /> Fourth quarter groundwater levels were measured at the PG&E Tracy Service Center on <br /> November 21, 1995, using an electronic sounding device, and recorded on the monitoring well <br /> data form included in Appendix A. The groundwater elevations are summarized in the table. <br /> The November data were used in constructing a groundwater contour map (see Figure 2). <br /> November water levels ranged from a low of 0.98 feet above mean sea level (MSL) in well <br /> OW-4 to a high of 1.50 feet above MSL in well OW-3. The estimated groundwater gradient is <br /> approximately 0.001 foot per foot(ft/ft) to the north. <br /> 3 SAMPLING, ANALYSIS, AND MONITORING PROGRAM RESULTS <br /> Groundwater samples were collected from well OW-2 on November 21, 1995, consistent with <br /> the protocol presented in Figure 3. The samples collected from well OW-2 were analyzed for <br /> gasoline by the U. S. Environmental Protection Agency (USEPA) Method 8015 Modified; and <br /> benzene, toluene, ethylbenzene, and xylenes (BTEX) by USEPA Method 8020. Field readings <br /> from the fourth quarter 1995 monitoring event are recorded on the water sample field data sheets <br /> (see Appendix A) and summarized in the table. <br /> The analytical results are discussed below. Fourth quarter 1995 and historical analytical data are <br /> summarized in the table. Certified analytical reports and chain-of-custody records are included in <br /> Appendix B. <br /> The samples taken from well OW-2 did not contain any detectable constituents. Toluene and <br /> total xylenes were detected in the trip blank at concentrations of 0.7 micrograms per liter (gg/L) <br /> and 0.8 gg/L, respectively. <br /> 4 FIELD AND LABORATORY QUALITY CONTROL RESULTS <br /> Analytical data were evaluated for accuracy and precision based on field and laboratory quality <br /> control (QC) sample performance. The field QC consisted of collecting one trip blank and <br /> analyzing it for gasoline and BTEX. <br /> The trip blank was collected to assess the effect of the sample bottles on the analytical results and <br /> to identify false positives. Toluene at 0.7 gg/L and total xylenes at 0.8 gg/L were detected above <br /> their respective method report limits in the trip blank, indicating some adverse effects from the <br /> bottles used in the sampling procedures. <br /> SACIN:1PJ010143101431150.1AS-961wpt:4 1 Rev.0,114/96 <br /> 0143-115.01 <br />