Laserfiche WebLink
5 . 0 ANALYTICAL RESULTS FOR SOIL AND GROUNDWATER <br /> SAMPLES COLLECT FROM THE CPT BORINGS <br /> All soil and groundwater samples collected from the CPT borings were <br /> analyzed by Kiff Analytical, LLC for TPH-G, BTEX, the fuel oxygenates MTBE, <br /> TBA, TAME, D1PE and ETBE, lead scavengers 1,2-DCA and 1,2-EDB, and the <br /> alcohols ethanol and methanol by EPA Method 8260 The analytical <br /> results for the soil samples collected from the CPT borings are tabulated <br /> in Table One The analytical results for groundwater samples collected <br /> from the CPT borings are tabulated in Table Two A copy of the certified <br /> analytical reports and chain of custody forms are included in Appendix D <br /> The soil sample collected at 7 0-feet bgs from boring CPT-1 contained 260 <br /> ppm TPH-G and 066 ppm ethyl benzene The soil sample collected at 7 0- <br /> feet bgs from boring CPT-2 contained 6,500 ppm TPH-G, 12 ppm benzene, <br /> 87 ppm toluene, 91 ppm ethyl benzene, 410 ppm total xylenes, and 0 56 <br /> ppm MTBE <br /> The benzene and total xylenes concentrations detected in soil samples <br /> collected from boring CPT-2 were the only compounds that exceeded the <br /> United States Environmental Protection Agency (USEPA) Region lx <br /> preliminary remediation goals (PRGs) for residential soil <br /> p The only compound detected above the laboratory reporting limit i n <br /> groundwater samples collected from boring CPT-2 at 41-feet bgs was total <br /> xylenes at 0 56 ppb The groundwater samples collected from boring <br /> CPT-2 at 37-feet bgs contained 74 ppb TPH-G, 3 0 ppb benzene, 2 3 p p b <br /> toluene, 2 5 ppb ethyl benzene, and 4 8 ppb total xylenes <br /> The benzene concentration inroundwater samples collected from g p am boring <br /> CPT-2 at 37-feet bgs was the only compound that exceeded <br /> g y p the California <br /> Department of Health Services (DHS) maximum contaminant level (MCL) <br /> for drinking water <br /> 6 . 0 DRILLING SOIL BORINGS FOR THE INSTALLATION OF <br /> GROUNDWATER MONITORING WELLS AND SAMPLE <br /> COLLECTION <br /> On October 5, 2000, Gregg Drilling of Martinez, California drilled soil <br /> borings MW-1 through MW-5 at the site using a Rhino limited access drill <br /> rig equipped with 8-inch diameter hollow stem augers (Figure 3) <br /> Groundwater monitoring wells MW-1 through MW-5 were subsequently <br /> 574 West Grant Line Road Report — October 2000 <br /> -5- <br />