Laserfiche WebLink
Table 3 <br /> Soil Boring and Well Construction Details <br /> i7-Eleven Site No 32262 <br /> 2360 West Grant Line Boulevard <br /> Tracy, California <br /> Well Screen Screen <br /> Well Drill Depth Diameter Top Bottom Length Comments <br /> I D Date (feel bgs) (inches) (feet bgs) (feel bgs) (feet) <br /> Tank Pit Wells <br /> TP-1 -- 12 -- -- -- 0 Removed during UST removal <br /> TP-2 -- 12 -- -- -- 0 Removed during UST removal <br /> TP-1 06/03/03 15 6 10 15 5 <br /> Monitoring Wells <br /> MW-1 10/16/03 17 2 7 17 10 <br /> MW-2 10/16/03 17 2 7 17 10 <br /> MW-3 10/16/03 17 2 7 17 10 <br /> MW-4 10/16/03 17 2 7 17 10 <br /> MW-5 10/16/03 17 2 7 17 10 <br /> MW--6D 10115-17103 32 83/4 -- -- -- Steel conductor 2 to 32 feet bgs <br /> 51 2 46 51 5 PVC Casing for Deep well <br /> Proposed Monitoring Wells <br /> MW-7 -- 17 2 7 17 10 <br /> MW-8 -- 17 2 7 17 10 Offsite well northwest of site <br /> MW-9 -- 17 2 7 17 10 Offsite well north of site <br /> Proposed Remediation Wells <br /> EX-1 -- 25 4 10 25 15 Groundwater extraction well <br /> S-1 -- 20 314 17 20 3 Oxygen injection well <br /> Proposed Soil Borings <br /> CPT-1 -- 80 -- -- -- -- Onsite CPT boring <br /> CPT-2 -- 80 -- -- -- -- Offsite CPT boring <br /> Explanation <br /> Wells are of polyvinyl chloride(PVC)construction <br /> bgs= Below ground surface <br /> UST=Underground storage tank <br /> 32262 WELL BORING SUM As Page 1 of 1 <br />