• Quarterly Report - First Quarter 2003 <br />' GRANT LINE GAS & FOOD <br /> 2420 Grant Line Road, Tracy, California <br />' 1.0. INTRODUCTION <br />' At the request of Mr Joe Toste Jr, Advanced GeoEnvironmental, Inc (AGE), has prepared this <br /> quarterly report for field activities performed at 2420 Grant Line Road,Tracy,California during the <br /> first quarter 2003 The site setting is illustrated in Figure 1 Monitoring well and boring locations on <br />' the site are illustrated in Figure 2 <br /> A detailed summary of previous work performed at the site was presented in the AGE-prepared <br />' documents titled Quarterly Report-March 1996,dated 15 April 1996 and Quarterly Report-March <br /> 1999, dated 10 May 1999 Monitoring and sample data from January 1994 to the present are <br /> summarized in Tables 1 through 3 of this report <br />' 2.0. PROCEDURES <br /> This report is prepared in accordance with Central Valley Regional Water Quality Control Board <br /> (CVRWQCB)guidelines for investigation of underground storage tank(UST) sites The field work <br /> was conducted in accordance with San Joaquin County Environmental Health Departinent(EHD) <br /> guidelines for sampling ground water monitoring wells <br /> 2 1 WELL MONITORING AND EVACUATION <br />' On 12 March 2003, the water levels in monitoring wells MW-1 through MW-8 were measured <br /> relative to the tops of the well casings using a Solinst water level meter After water levels were <br />' measured, wells MW-1 through MW-8 were evacuated (purged) utilizing a dedicated, disposable <br /> plastic bailer, approximately 15 to 6 gallons (a minimum of three casing-water volumes per well) <br /> of water were removed from each well Temperature, pH and conductivity of the purged ground <br />' water were measured at regular intervals using an Oakton water analyzer during purging, the <br /> measurements had stabilized by the end of the purging process Purged water was stored on-site in <br /> labeled 55-gallon,Department of Transportation(DOT)-approved drums Field logs are included in <br />' Appendix A <br />' 22 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br />' Prior to collection of ground water samples, the depth to ground water was gauged in the purged <br /> wells to ensure that a minimum of 80%of the initial well volume had recharged Afterwards,water <br /> samples were collected from each well using the dedicated,disposable plastic bailer and transferred <br />' into three chilled 40-m1 volatile organic analysis (VOA) vials containing 0 5 ml 18%hydrochloric <br /> Advanced GeoEnv uonmental Inc <br />