PR0508461
PE
2950
FACILITY_ID
FA0008092
FACILITY_NAME
CONTINENTAL GRAIN CO
STREET_NUMBER
1805
STREET_NAME
HARBOR
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14502005
CURRENT_STATUS
01
SITE_LOCATION
1805 HARBOR ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. CORRECTIVE ACTION OBJECTIVE <br /> As discussed in Section 3 4, the small pocket of affected groundwater is not migrating and will <br /> not impact surface water or water supply wells As discussed in Section 3 5, the residual <br /> petroleum does not likely pose a human health risk Therefore, corrective actions are only <br /> focused upon soil source removal Removal of this source will reduce any future potential for <br /> migration, remove free product, and will assist the natural attenuation of the groundwater <br /> concentrations <br /> 5. CORRECTIVE ACTION ALTERNATIVES EVALUATION <br /> ' A total of seven corrective action alternatives were previously evaluated in two CAPS submitted <br /> for this site The most recent CAP, dated October 5, 2004, evaluated alternatives including <br /> natural attenuation, air sparging/SVE, low temperature thermal desorption, and excavation <br /> ' Further refinement of the CAP alternatives is provided in this Addendum Three additional <br /> options are presented for excavation/off-site disposal to further determine the cost effectiveness <br /> of source removal For each alternative the costs, mass of TPH removed, effect on free product, <br /> ' and an estimate of time to achieve compliance with WQOs were compared to determine the most <br /> appropriate alternative for the Stockton Elevator <br /> ' This Addendum to the CAP presents the following three alternatives for excavation and off-site <br /> disposal of affected soil <br /> Alternative Al Excavation and off-site disposal with remedial goal addressing soils to <br /> 500 mg/kg TPH boundary (includes beth dewatering and shoring to remove soil to a <br /> depth of up to 28 feet deep or approximately 14 to 17 feet into the water table) <br /> ' . Alternative A2 Excavation and off-site disposal to approximately five feet into water <br /> table, expanding out laterally to area of MW-3 (does not include shoring, may or may not <br /> include dewatering) <br /> Alternative A3 Excavation and off-site disposal as combination of above options, to <br /> approximately 28 feet deep and laterally expanded to MW-3 (requires both shoring and <br /> ' dewatenng) <br /> 5 1 Alternative Al Excavation of soils containing 500 mg/kg TPH or more <br /> The focus of Alternative Al was to remove all soils containing more than 500 mg/kg of TPH <br /> This particular soil objective is based upon the ESL from the San Francisco Bay Region and <br /> represents the most conservative soil screening level for TPH where groundwater is a potential <br /> drinking water resource Therefore, this ESL does not apply directly to the Stockton Elevator <br /> but rather provided a baseline for comparison of source area removal <br /> The area to be excavated is defined by both historic soil borings and the soil samples collected in <br /> 2004 The lateral boundaries of this area were HA-8, HA-9, the utility pole, and MW-4 This <br /> area extends laterally approximately 67 5 ,ft by 20 ft and compares to Alternative 3 and <br /> Alternative 4 in the October 2004 CAP that measured 35 ft by 30 ft in size To remove all soils <br /> with a concentration of more than 500 mg/kg TPH requires excavation into the water table <br /> 16 <br /> R%CONTGRANIStockton\CAP\CAP ADDENDUM <br /> I <br />