Laserfiche WebLink
TABLE 2 <br /> Laboratory Analysis of Water Samples <br /> Knowles Property - Stockton, CA <br /> Page 4 of 4 <br /> (in PPb) <br /> SAMPLE DATE WELL ID 8 T E X TPHO <br /> 08/31/93 MW1 120 4 6 19 34 1,400 <br /> MW2 1 5 1 5 <0 50 <0 50 870 <br /> MW3 DRY WELL <br /> MW4 25 <0 50 <0 50 <0 50 530 <br /> MW5 20,000 12,000 2,000 7,200 140,000 <br /> MW6 <0 50 <0 50 <0 50 <0 50 <50 <br /> MW7 <0 50 <0 50 <0 50 <0 50 <50 <br /> MW8 <0 50 <0 50 <0 50 <0 50 <50 <br /> 12/16/93 MW1 <0 50 <0 50 <0 50 <0 50 <50 <br />. MW2 <0 50 <0 50 <0 50 <0 50 <50 <br /> MW3 DRY WELL <br /> MW4 1 1 068 <0 50 <0 50 <50 <br /> MW5 NA NA NA NA NA <br /> MW6 <0 50 <0 50 <0 50 <0 50 <50 <br /> MW7 <0 50 <0 50 <0 50 <0 50 <50 <br /> MW8 <0 50 <0 50 <0 50 <0 50 <50 <br /> NOTES <br /> ppb — parts per billion = uglf = micrograms per liter <br /> B = Benzene, Analyzed by EPA Method 8020 <br /> T — Toluene, Analyzed by EPA Method 8020 <br /> E = Ethylbenzene, Analyzed by EPA Method 8020 <br /> X = Xylenes, Analyzed by EPA Method 8020 <br /> TPHG = Total Petroleum Hydrocarbons as Gasoline, Analyzed by EPA Method 8015 <br /> < — Not Detected at or Above Method Detection Limits <br /> = Sample chromatogram does not match gasoline fingerprint <br /> 2 = Sample chromatogram contains an unidentified peak which does not match gasoline fingerprint <br /> s — When compared to the gasoline standard, chromatogram contains a higher proportion of peaks <br /> that elute before benzene <br /> NA = Not Analyzed <br /> s90 93TABL.L4B <br />