RECORD_ID
PR0545245
PE
3528
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
02
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
317
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conditions for N-5036-1-0 (continued) <br /> Page 2 of 2 <br /> 9. Neither the soil ventilation rate nor the effluent gas flow rate shall exceed 250 scfm through the carbon canisters. <br /> [District Rule 22011 <br /> 10. The catalytic oxidizer shall be equipped with an operational temperature gauge to indicate the temperature of the <br /> combustion chamber. A continuously recording device shall be utilized to indicate the combustion chamber <br /> temperature during operation of the catalytic oxidizer. [District Rule 2201] <br /> 11. When VOC emissions are controlled by the catalytic oxidizer the soil remediation system shall not be operated unless <br /> the combustion chamber of the functioning catalytic oxidizer is at or above the minimum operating temperature. The <br /> system shall automatically terminate operation if the temperature drops below the minimum operating temperature. <br /> [District Rule 2201] <br /> 12. When VOC emissions are controlled by the catalytic oxidizer the minimum operating temperature for the combustion <br /> chamber of the catalytic oxidizer shall be maintained at or above 600 degrees F. [District Rule 2201] <br /> 13. When VOC emissions are controlled by the catalytic oxidizer, only natural gas shall be used as auxiliary fuel for the <br /> combustion of VOCs. [District Rule 2201] <br /> 14. When VOC emissions are controlled by the carbon adsorption system, a minimum of four carbon canisters (of 200 lbs <br /> each) which are connected in series shall be utilized. [District Rule 22011 <br /> 15. The carbon canisters removed from the system shall be sealed vapor tight. [District Rule 220 1] <br /> 16. Sampling ports adequate for extraction of grab samples, measurement of gas flow rate, and use of an FID, PID or other <br /> District-approved VOC detection device shall be provided for both the influent and effluent gas streams. [District Rule <br /> 1081] <br /> 17. Laboratory samples shall be taken at the initial inspection, under the supervision of the APCD Inspector. Samples shall <br /> be taken from both the influent and the effluent gas stream sampling ports. [District Rule 108 1] <br /> 18. Laboratory samples shall be analyzed for TPH and BTEX. [District Rule 1081] <br /> 19. Measurements to determine the influent and the effluent gas flow rates shall be taken at the initial inspection. Flow rate <br /> calculations shall be submitted to the District with the laboratory sample analysis results. [District Rule 1081] <br /> 20. Initial compliance with VOC emission rate and control efficiency shall be demonstrated by the results of the laboratory <br /> analysis. The results shall be submitted to the District within 60 days of the test. [District Rule 108 11 <br /> 21. Ongoing compliance with VOC emission rate and control efficiency requirements shall be demonstrated by sampling <br /> both the influent and the effluent gas streams with an FID,PID, or other District-approved VOC detection device. <br /> [District Rule 1081] <br /> 22. Sampling to demonstrate ongoing compliance shall be performed at]cast once per month when utilizing the catalytic <br /> oxidizer, and at least once per week when utilizing the carbon canisters. [District Rule 1081] <br /> 23. Records of the cumulative running time and the measured influent and effluent VOC concentrations shall be <br /> maintained. [District Rule 1070] <br /> 24. All records shall be retained for a minimum of 5 years, and shall be made available for District inspection upon <br /> request. [District Rule 1070] <br /> 25. The Air Pollution Control Inspector shall be notified in writing when the soil remediation system will be modified to <br /> change from one type of control equipment to another prior to the modification. [District Rule 2201] <br /> N-5035-1-0ftv 3 2003 8'.05AM-GOOOW INR <br />