My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
9504
>
2900 - Site Mitigation Program
>
PR0508462
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 12:22:14 PM
Creation date
1/30/2020 11:02:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508462
PE
2960
FACILITY_ID
FA0008093
FACILITY_NAME
CONTINENTAL GRAIN CO
STREET_NUMBER
9504
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
9504 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO.R5-2004-0160 -2- <br /> CONTIGROUP COMPANIES,INCORPORATED <br /> FRENCH CAMP GRAIN ELEVATOR <br /> ENHANCED REMEDIATION PILOT STUDY <br /> SAN JOAQUIN COUNTY <br /> Field measured parameters shall follow the schedule below: <br /> Parameters Units Type of Sample Sampling Frequency <br /> Groundwater Elevation Feet,Mean Sea Level Grab Every time MW-3B,MW-413, <br /> Oxidation-Reduction Potential Millivolt Grab MW-9B,and MW-10B are <br /> Electrical Conductivity uhmos Grab sampled <br /> Dissolved Oxygen mwi Grab <br /> H 0.1 units Grab <br /> Field testing instruments (such as those used to test oxidation-reduction potential and dissolved oxygen) <br /> may be used provided that: <br /> 1. The operator is trained in proper use and maintenance of the instruments'-- <br /> 2. <br /> nstruments;2. The instruments are field calibrated prior to each monitoring event; <br /> 3. Instruments are serviced and/or calibrated by the manufacturer at the recommended frequency; <br /> and <br /> 4. Field calibration reports are provided with the appropriate monitoring report. <br /> REPORTING <br /> In reporting monitoring data,the Discharger shall arrange the data in tabular form so that the date, <br /> sample type, and reported analytical result for each sample are readily discernible. The data shall be <br /> summarized in such a manner to clearly illustrate compliance with waste discharge requirements and <br /> spatial or temporal trends, as applicable. The results of any monitoring done more frequently than <br /> required at the locations specified in the MRP shall also be reported to the Regional Board. <br /> As required by the California Business and Professions Code Sections 6735, 7835, and 7835.1, all <br /> Groundwater Monitoring Reports shall be prepared under the direct supervision of a Registered Engineer <br /> or Geologist and signed by the registered professional. <br /> Quarterly reports shall be submitted to the Board by the 1st day of the second month following the end <br /> of each calendar quarter(i.e.,by 1 February, 1 May, 1 August, and I November). The reports shall <br /> be submitted separately from the quarterly monitoring reports required by MRP No. 5-00-858. At a <br /> minimum,the reports shall include: <br /> 1. Results of monitoring, including a narrative description of all preparatory,monitoring, sampling, and <br /> analytical testing activities for the groundwater monitoring. The narrative shall be sufficiently <br /> detailed to verify compliance,with the WDR,this MRP, and the Standard Provisions and Reporting <br /> Requirements. The narrative shall be supported by field logs for each well documenting depth to <br /> groundwater;parameters measured before,during, and after purging; calculation of casing volume; <br /> total volume of water purged, etc.; <br /> 2. Copies of all laboratory analytical report(s); <br /> 3. Cumulative data tables containing the water quality analytical results and depth to groundwater; <br />
The URL can be used to link to this page
Your browser does not support the video tag.