My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1767
>
3500 - Local Oversight Program
>
PR0545247
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 12:44:05 PM
Creation date
1/30/2020 11:11:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545247
PE
3528
FACILITY_ID
FA0009790
FACILITY_NAME
CITY OF STOCKTON FIRE STATION #7
STREET_NUMBER
1767
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07509036
CURRENT_STATUS
02
SITE_LOCATION
1767 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Stockton sites <br /> Page 2 <br /> 134 Sutter <br /> The soil sample collected beneath the underground storage tank (UST), formerly located <br /> where the Market Street Parking Garage office is currently located, did not evidence <br /> contamination. However, the soil sidewall of the UST excavation was observed to have <br /> contamination at the time the UST was removed and PHS/EHD staff advised the <br /> contractor that the area would have to be investigated, if a sample was not obtained at <br /> that time. PHSIEHD has requested further investigation of this area in previous <br /> correspondence. A monitoring well has been installed about 50 feet west of this former <br /> area as part of another site investigation (145 S. Sutter Street. Stockton)_ After reviewing <br /> the groundwater sample results from this monitoring well and inspecting the site, <br /> PHS/EHD has determined that further investigation should not be required and will <br /> request concurrence on this determination from the Central Valley Regional Water Quality <br /> Control Board. <br /> 1701 Washington <br /> The closure plan to close the underground storage tank piping in place has been <br /> submitted to PHS;EHD. Once the piping is closed in place PHSIEHD will request <br /> concurrence from the Central Valley Regional Water Quality Control Board (CVRWQCS) <br /> for no further action required at this site. <br /> 1767 Hammer <br /> A report of the mass of contaminants remaining at this site has been submitted to <br /> PHSIEHD. After PHSIEHD review of the report, concurrence from CVRWQCB for no <br /> further action required at this site may be requested. <br /> Royal Oaks at Princess <br /> The City of Stockton Municipal Utilities staff had previously informed PHS/EHD staff that a <br /> work plan to investigate the site would be submitted. To date a work plan has not been <br /> received. PHSIEHD staff reviewed the file and inspected the site an October 27, 1998. A <br /> work elan to define the lateral and vertical extent of the soil contamination (through 2 or 3 <br /> probes or borings) and determine if a groundwater investigation is necessary should be <br /> submitted by January 15, 1999.. <br /> 1465 Lincoln <br /> This site has been placed an the PHSIEHD contaminated site list_ PHSIEHD staff <br /> observations in April 1995, when three 12,000 gallon USTs were removed, and the <br /> laboratory data from the soil samples collected beneath the south ends of those USTs <br /> indicate there is soil contamination. The soil samples collected during an environmental <br /> assessment in April 1994 evidenced some contamination at 20 feet below ground surface <br /> (bgs). Groundwater is currently at about 25 feet bgs. A work plan to define the lateral <br /> and vertical extent of the soil contamination and determine if a groundwater investigation <br /> is necessary should be submitted by January 15, 1999. In addition, there is piping <br /> associated with a former 1000-gallon waste oil UST that has not been sampled beneath <br /> and the piping still requires closure in place. <br />
The URL can be used to link to this page
Your browser does not support the video tag.