Laserfiche WebLink
L City of Stockton <br /> A68109.OIB <br /> July 18, 1997 Page A-5 <br /> Latmosphere. After approximately 15 minutes which is generally sufficient t £or some of the <br /> volatiles to escape from the soil, the PID probe or tip of the drager tube is inserted into the <br /> container and the gas is sampled. The highest concentration of organic vapors recorded by <br /> the PID or the drager tube reading will be recorded. <br /> A-7 Standard Operating Procedures for Decontamination Rinsate Monitoring Well <br /> Purge Water, and Soil Cuttings Disposal: The soil cuttings generated by drilling operations <br /> are retained on site, and either covered by plastic sheeting or containerized in United States <br /> Department of Transportation (DOT)-approved drums. The drilling equipment <br /> decontamination rinsate is also stored in drums. Drums containing soil and rinsate are <br /> sealed and temporarily stored on site at a location remote to the public. Each drum is <br /> El labelled to identify its contents. Disposal of these wastes will be the responsibility of the <br /> client. The client will be informed that the wastes must be disposed in accordance with <br /> applicable Federal, State, and local regulations. <br /> 1 <br /> 7 <br />