My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
117
>
3500 - Local Oversight Program
>
PR0545260
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 3:52:52 PM
Creation date
1/30/2020 11:48:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545260
PE
3528
FACILITY_ID
FA0005325
FACILITY_NAME
INLAND PAINT COMPANY
STREET_NUMBER
117
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
12707031
CURRENT_STATUS
02
SITE_LOCATION
117 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> leaking Underground Underground Fuel Storage Tarlrogram <br /> III Release and Site Characterization Information continued <br /> Maximum Documented Contaminant Concentrations - -Before and After Cleanup <br /> Contaminant Soil (ppm) Water (ppm) Contaminant Soil (ppm) Water (ppm) <br /> Before. After Before After Before After Before After <br /> TPH (Gas) 3,300. <0.1 9.0 1.7 Ethyl-benzene <1.2 <0.005 0.0564 .0043 <br /> TPH (Diesel) 5,800. <0.1 63. 1.9 Xylene 6.2 <0.01 0.210 0.034 <br /> TPH (Stoddard) 4,500. NA** 110. 1.9 1,2-DCX <5.0 <0.005 . 0.0020 NA <br /> Benzene. 6.3 <0.005 0.0013 <0.0005 EDB <5.0 <0.005 <0.005 NA <br /> Toluene <1.2 <0.005 0.013-,. <0.0005 Lead 7.6 NA„ NA NA <br /> MtBE <7.0 <0.005 <0.0066 NA <br /> Comments NOTE. GROUNDWATER RESULTS IN PARTS PER MILLIONI <br /> *: 1,2-Dichloroethane. **: Not analyzed after first time <br /> Over-excavation was the only remediation performed at the site. Monitoring wells 1,2 &3 sampled quarterly for 2.5 <br /> years(10 times) since installation in September 1998. MW-4 installed offsite and upgradient on 4-10-00 and <br /> sampled four times during 2000 only(always non-detect). TAME, DIPE,TBA ETBE sampled one time in soil and <br /> groundwater by 8260 on September 18, 1998 and non-detect at acceptable detection limits. MW-3 (informer UST <br /> pit) hottest of all wells and soil and groundwater data listed above from this well. Hottest detection is initial <br /> sampling event('before' column) and most current groundwater or deepest soil data in 'after'`column. Most <br /> current groundwater-sampling event done on 12-08-00. <br /> IV. Closure <br /> Does completed corrective action protect existing beneficial uses per the Regional Board Basin Plan? YES <br /> Does completed corrective action protect potential beneficial uses per the Regional Board Basin Plan? YES <br /> Does corrective action protect public health for current land use? YES <br /> Site management requirements: none <br /> Should corrective action be reviewed if land use changes? Not necessary <br /> Have the Monitoring/Vapor wells been decommissioned?YES Number Decommissioned: 4 Number retained: 0 <br /> List enforcement actions taken: NOR, 4-24-97 <br /> List enforcement actions rescinded: nla <br /> V. Local Agency Representative Data <br /> Name: Donna Heran Title: Director of Environmental Health <br /> Signature: Date: <br /> uYVyLcL ,t�tc <br /> VI. Central Valley Regional Water Quality Control Board RB Notification <br /> Date Submitted to RB: August 2,2001 Response Date: September 7,2001 <br /> RB Staff: Marty Hartzell Response: Concurrence <br /> Title. Engineering Geologist <br /> VII. Additional Comments, Data, etc <br /> Only corrective action proposed or conducted at site was over-excavation of 70 cubic yards of soil in former UST <br /> pit area under PHS-EHD approval and oversight in September 1998. Slant boring "SB-2A" installed south of UST <br /> pit and MW-3 area under building to determine 'south quadrant' delineation on March 23, 2000. The boring was <br /> advanced 30 degrees off of vertical towards the south to x-30' bgs. Soil and groundwater samples were non-detect <br /> for TPH as G, D, &SS, and BTEX and five oxygenates. Well survey indicated no drinking water wells threatened. <br /> All four 4 monitoring wells properly destroyed under EHD permit and oversight,2114102. <br /> This document and the related CASE CLOSURE LETTER shall be retained by the lead agency as part of the official' 1 <br /> site file. 1 <br /> M 117101 ` <br />