Laserfiche WebLink
SANJOARIN Environmental Health Department <br /> —COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> F.61 it,N.. I Facility Address: aae. <br /> RAMOS OIL CAR D LOCK 8925 WTHORNTON RD,THORNTON January 23, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item M Remarks <br /> 612 CFR 112.7(c)Plan failed to include secondary containment,diversionary structures,or equip to prevent discharge. <br /> The facility has buried piping and general secondary containment for the piping is not discussed. <br /> Provide appropriate containment and/or diversionary structures or equipment to prevent a discharge as described in <br /> §112.1(b),except as provided in paragraph(k)of this section for qualified oil-filled operational equipment,and <br /> except as provided in§112.9(dx3)for flo Mines and intra-facility gathering lines at an oil production facility.The <br /> entire containment system,including walls and floor,must be capable of containing oil and must be constructed so <br /> that any discharge from a primary containment system,such as a tank,will not escape the containment system <br /> before cleanup occurs. In determining the method,design,and capacity for secondary containment, you need only <br /> to address the typical failure mode,and the most likely quantity of oil that would be discharged.Secondary <br /> containment may be either active or passive in design.At a minimum,you must use one of the following prevention <br /> systems or its equivalent: <br /> (1)For onshore facilities: <br /> (i)Dikes, berms,or retaining walls sufficiently impervious to contain oil; <br /> (ii)Curbing or drip pans; <br /> (iii)Sumps and collection systems; <br /> (iv)Culverting,gutters,or other drainage systems; <br /> (v)Weirs,booms,or other barriers; <br /> (vi)Spill diversion ponds; <br /> (vii)Retention ponds;or <br /> (viii)Sorbent materials. <br /> (2)For offshore facilities: <br /> (i)Curbing or drip pans;or <br /> (ii)Sumps and collection systems. <br /> The SPCC plan should address appropriate containment and/or diversionary structures or equipment to prevent a <br /> discharge,except for qualified oil-filled operational equipment when other requirements are met, and except for <br /> flowlines and intra-facility gathering lines at an oil production facility. <br /> This is a Class II violation. <br /> FM0179U PRODU78 50001 01Q32020 <br /> EHD 18U1 Rcr.QrXV2W9 Page 6 of Abaveg clPetro—Stara)e AC OIR <br /> 1868 E. Hazelton Avenue I Stockton,California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehdCom <br />